KRIWAN MOTOR PROTECTOR INT69-2 DIAGNOSE ( 22A445S80 )
Application
| PRODUCT DETAILS | |
| Application | Compressors acc. IEC/EN 60335 | 
| Function | Motor temperature static, Motor temperature dynamic, Short circuit. | 
| Supply voltage | AC 115 -240V | 
| Permitted ambient temperature | -30...+70°C | 
| Temperature measuring circuits: Type  | 
			1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN /44081, DIN /44082 in series | 
| Temperature measuring circuits: R_25, total  | 
			<1.8kΩ | 
| Temperature measuring circuits: R_trip  | 
			4.5kΩ ±20% | 
| Temperature measuring circuits: R_trip, static  | 
			4.5k!& ±20% | 
| Temperature measuring circuits: R_reset  | 
			2.75kΩ ±20% | 
| Temperature measuring circuits: Max. length connection line | 30m | 
| Short circuit monitoring system PTC | Typically <30Ω | 
| Input, operating recongnition motor: Lower limit | AC 100V at 20Hz to 175V at 90Hz | 
| Input, operating recongnition motor: Upper limit | AC 460V ±15% | 
| Operating with frequency converters | Suitable | 
| Reset delay: Motor temperature static | 1min ±12s | 
| Reset delay: Motor temperature dynamic | 5min ±1min | 
| Resetting the lock or the reset delay | Main reset >5s only possible if there is no error current | 
| Relay: Connection | AC 240V 2.5A C300 at least AC/DC 24V 20mA | 
| Relay: Mechanical service life | Approx. 1 million switching cycles | 
| Interface | Diagnose port (DP) | 
| Protection class acc. To EN 60529 | IP00 | 
| Connection type | screw type terminals | 
| Housing material | PA glass-fibre-reinforced | 
| Mounting | screw mounted | 
| Dimensions | Refer to dimensions in mm | 
| Weight | Approx. 150g | 
| Check base | IEC/EN /60335, IEC/EN /60730, UL /60730 EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2 | 
| Approval | UL /File /no. /E75899 cURus /VDE /certification /no. /40022017 |