Description
Schneider Electric PowerLogic PM5000 Series
PowerLogic PM5320 Power Meter with Ethernet
The Schneider Electric PowerLogic PM5320, commercial reference METSEPM5320, is a flush-mount PM5000 series power meter with Ethernet communication, 31st harmonic measurement, onboard data memory and digital I/O. It is designed for panel metering, sub-metering, energy monitoring and basic power quality visibility.
The PM5320 is suitable for LV switchboards, MCC panels, distribution boards, feeder panels, utilities, production lines and equipment panels where continuous electrical data must be collected over Ethernet for EMS, BMS, SCADA, EcoStruxure Power Monitoring Expert or IoTWatt 4.0.
Model METSEPM5320 / PM5320
Communication Ethernet
Harmonics Up to 31st harmonic
I/O and Memory 256 kB, 2DI / 2DO
Product Overview
The PowerLogic PM5320 is part of Schneider Electric’s PM5000 multi-function metering range. It provides accurate power and energy measurement together with Ethernet communication, making it suitable for network-based energy monitoring and building or industrial automation systems.
Compared with RS485-only models, the PM5320 is easier to integrate into Ethernet-based monitoring networks. It is suitable where metering data needs to be collected directly through an IP network without an additional RS485 gateway.
Positioning: Flush-mount Ethernet power meter with 31st harmonic measurement, 256 kB onboard memory and 2DI / 2DO for energy monitoring, sub-metering and IoTWatt 4.0 integration.
Typical Monitoring Architecture
The PM5320 is installed at the electrical panel and communicates through Ethernet to a monitoring system, SCADA, EMS, BMS, EcoStruxure Power Monitoring Expert or IoTWatt 4.0 platform.
1 CT / Voltage Inputs
2 PM5320 Meter
3 Ethernet Network
4 IP Meter Data
5 EMS / BMS / IoTWatt
Key Features
Flush-Mount Design
Designed for panel-front mounting in LV switchboards, distribution panels, feeder panels and MCCs.
Ethernet Communication
Supports direct connection to Ethernet-based monitoring systems without requiring an RS485 gateway.
Class 0.5S Energy Accuracy
Provides accurate active energy measurement for reliable panel metering and sub-metering applications.
31st Harmonic Measurement
Provides individual harmonic visibility up to the 31st order for better electrical distortion review.
256 kB Onboard Memory
Supports local logging and data storage for trend review and energy monitoring applications.
2 Digital Inputs / 2 Digital Outputs
Supports pulse, status and control-related applications depending on site configuration.
Alarm Capability
Supports alarm functions for panel-level electrical supervision and operating alerts.
5A or 1A CT Input
Supports conventional current transformer secondary inputs of 5A or 1A.
600V AC L-L Measurement
Suitable for low-voltage electrical systems up to 600V AC line-to-line.
Applications
The PM5320 is suitable for installations that require panel-level measurement, Ethernet-based data collection, data logging, digital I/O and better harmonic visibility than basic meters.
Industrial Energy Monitoring
Monitor feeders, utilities, compressors, chillers, pumps, production lines and major electrical loads.
Sub-Metering and Cost Allocation
Measure energy by feeder, tenant, department, process area or major equipment group.
Power Quality Visibility
Use 31st harmonic data to understand distortion from drives, UPS systems, nonlinear loads and process equipment.
Demand and Load Review
Monitor kW, kVA, current, demand and load behaviour for operational and capacity review.
Power Factor Management
Track power factor and reactive power behaviour to support capacitor bank and penalty review.
IoTWatt 4.0 Integration
Use Ethernet meter data for dashboards, alarms, analytics, energy audit and EECA reporting workflows.
Model and Main Characteristics
| Item |
PM5320 / METSEPM5320 |
| Product Family |
Schneider Electric PowerLogic PM5000 series |
| Commercial Reference |
METSEPM5320 |
| Description |
Power Meter, 600V AC L-L / 5A or 1A input, 415V AC L-L or 250V DC control power, Class 0.5S, 31st harmonic, 256 kB, 2DI / 2DO, Ethernet |
| Mounting |
Flush mount panel meter |
| Communication |
Ethernet communication |
| Protocol / Integration |
Ethernet-based integration for energy monitoring, EMS, BMS, SCADA and IoTWatt 4.0 systems |
| Current Input |
5A or 1A CT input |
| Voltage Rating |
600V AC line-to-line |
| Control Power |
415V AC line-to-line or 250V DC control power |
| Active Energy Accuracy |
Class 0.5S |
| Harmonic Measurement |
Up to 31st harmonic |
| Memory |
256 kB onboard memory |
| Digital Inputs / Outputs |
2 digital inputs / 2 digital outputs |
| Alarm Capability |
35 alarms |
Measured Parameters
| Parameter Group |
Typical Values Measured |
| Voltage |
Line-to-line and line-to-neutral voltage values depending on wiring configuration. |
| Current |
Phase current values through 5A or 1A CT secondary inputs. |
| Power |
Active, reactive and apparent power for load monitoring. |
| Energy |
Active and reactive energy for metering, sub-metering and cost allocation. |
| Power Factor |
Power factor values for capacitor bank and reactive power review. |
| Frequency |
System frequency measurement. |
| Demand |
Demand values for load and peak usage review. |
| Harmonics |
Harmonic visibility up to 31st harmonic. |
Communication, Logging and Integration
The PM5320 includes Ethernet communication and onboard memory, making it suitable for networked monitoring and local data logging applications. The meter can be integrated into energy monitoring software, EMS, BMS, SCADA, EcoStruxure Power Monitoring Expert and IoTWatt 4.0.
| Integration Requirement |
PM5320 Capability |
| Local Panel Display |
Supported through the meter display. |
| Ethernet Monitoring |
Supported through built-in Ethernet communication. |
| Local Data Logging |
Supported through 256 kB onboard memory. |
| Digital Input Monitoring |
2 digital inputs can support status or pulse-related monitoring depending on configuration. |
| Digital Output Function |
2 digital outputs can support pulse or control-related functions depending on configuration. |
| EMS / BMS / SCADA |
Can be integrated through an Ethernet network. |
| EcoStruxure PME |
Suitable for integration into Schneider Electric power monitoring environments. |
| IoTWatt 4.0 |
Can be integrated over Ethernet for dashboards, alarms, analytics and digital energy audit workflows. |
Integration note: For IoTWatt 4.0, PM5320 can be connected through the site Ethernet network. This avoids the need for an additional RS485-to-IP gateway when Ethernet connectivity is available at the panel.
Why Use PowerLogic PM5320?
The PM5320 is suitable when the project needs a Schneider Electric power meter with Ethernet connectivity. It provides better network integration than RS485-only meters while retaining strong PM5000 metering features such as 31st harmonic visibility, onboard memory and digital I/O.
- Provides local display and Ethernet communication.
- Supports Class 0.5S active energy accuracy for reliable energy measurement.
- Provides harmonic visibility up to the 31st order.
- Includes 256 kB onboard memory for logging applications.
- Includes 2 digital inputs and 2 digital outputs.
- Useful for EMS, BMS, SCADA, EcoStruxure PME and IoTWatt 4.0 integration.
- Suitable for sub-metering, demand monitoring, power factor review and energy audits.
Integration with IoTWatt 4.0
IoTWatt 4.0 can use PM5320 meter data for energy dashboards, demand analytics, power factor tracking, harmonic visibility, equipment-level monitoring, EECA reporting and digital energy audit workflows. Ethernet communication makes it practical for direct IP-based data collection.
- Monitor kWh, kW, current, voltage, power factor, demand and harmonic values.
- Use energy data for baseline creation, load profiling and abnormal consumption detection.
- Support energy audit findings with measured electrical data.
- Track achieved savings after corrective actions.
- Use digital inputs for auxiliary status or pulse monitoring where required.
- Use Ethernet connectivity for faster and cleaner system integration where LAN is available.
- Support EECA reporting and continuous energy performance improvement.
Recommended Deployment Checklist
- Confirm the electrical system voltage and wiring configuration.
- Confirm CT secondary rating: 5A or 1A.
- Confirm CT ratio, CT class, CT burden and CT polarity.
- Confirm panel cut-out, flush mounting space and wiring clearance.
- Confirm control power availability: 415V AC L-L or 250V DC.
- Confirm Ethernet network availability, IP address, gateway, subnet and cybersecurity requirements.
- Confirm communication protocol and register mapping required by EMS, BMS, SCADA, PME or IoTWatt 4.0.
- Confirm logging requirement and how the 256 kB memory will be used.
- Confirm 2DI / 2DO usage for pulse, status, alarm or control-related functions.
- Confirm dashboard, alarm, analytics and EECA reporting requirements for IoTWatt 4.0.
- Test voltage phase sequence, CT direction, readings, alarms, I/O and communication during commissioning.
PowerLogic PM5320 Supply, Commissioning and IoTWatt 4.0 Integration
Saturn Pyro supports Schneider Electric PowerLogic PM5320 meters for flush-mount panel metering, Ethernet integration, 31st harmonic monitoring, sub-metering, demand review, EMS / BMS / SCADA communication and IoTWatt 4.0 digital energy audit projects in Malaysia.
Enquire Now
More detail about Saturn Pyro Sdn Bhd