Description
Schneider Electric EasyLogic PM2200 Series
EasyLogic PM2210 Power & Energy Meter
The Schneider Electric EasyLogic PM2210, commercial reference METSEPM2210, is a compact panel-mounted power and energy meter for basic electrical monitoring, energy metering and total harmonic distortion visibility. It is suitable for LV panels, distribution boards, MCC panels and sub-metering points where local display and pulse output are required.
The PM2210 provides Class 1 active energy measurement, power and energy values, voltage, current, frequency, power factor, demand values, total harmonic distortion and pulse output. It is a practical entry-level Schneider Electric meter for basic panel metering and energy visibility.
Model METSEPM2210 / PM2210
Series EasyLogic PM2200
Accuracy Class 1 active energy
Output Pulse output
Product Overview
The EasyLogic PM2210 is designed for users who need a simple and reliable power meter for panel-level electrical measurement. It provides local display of key power and energy parameters and supports pulse output for external energy counting or basic integration.
It is suitable for projects where the priority is cost-effective metering, local visibility and pulse-based energy monitoring rather than full RS485 Modbus or Ethernet communication.
Positioning: Entry-level Schneider Electric panel power and energy meter with Class 1 accuracy, total harmonic distortion measurement, local display and pulse output.
Typical Monitoring Architecture
The PM2210 is installed at the electrical panel for local measurement. Its pulse output can be connected to a pulse counter, data logger, PLC, remote I/O module or IoTWatt 4.0 gateway where pulse-based kWh monitoring is required.
1 CT / Voltage Inputs
2 PM2210 Meter
3 Pulse Output
4 Pulse Counter / I/O
5 EMS / IoTWatt
Key Features
Class 1 Energy Accuracy
Suitable for basic energy metering, sub-metering and panel-level consumption monitoring.
Local Display
Provides local display of key electrical parameters for quick panel-side checking and operation review.
Total Harmonic Distortion
Supports THD visibility for voltage and current to provide basic power quality awareness.
Pulse Output
Provides pulse output for external kWh counting, data logging or simple integration.
1A / 5A CT Input
Supports standard current transformer secondary inputs for LV panel metering applications.
96 mm Panel Format
Compact 96 mm × 96 mm panel meter format suitable for common switchboard and distribution panel cut-outs.
Power and Energy Values
Displays active, reactive and apparent power and energy values for electrical visibility.
Demand Monitoring
Supports demand values for basic load and consumption review.
Cost-Effective Metering
Suitable for basic panel metering where advanced communication is not required.
Applications
The PM2210 is suitable for basic power and energy monitoring applications in commercial, industrial and facility electrical systems.
Distribution Board Metering
Use at DBs and sub-distribution panels to monitor energy and electrical load.
Feeder Sub-Metering
Measure energy by feeder, tenant, department, production area or major equipment group.
Basic Energy Monitoring
Use pulse output for kWh collection into pulse counters, PLCs or remote I/O systems.
Panel Upgrade
Replace analogue meters with a digital panel meter that displays multiple electrical parameters.
Power Factor Review
Track power factor and load behaviour for capacitor bank and reactive power review.
Basic THD Visibility
Use THD values for basic awareness of distortion from nonlinear electrical loads.
Model and Main Characteristics
| Item |
PM2210 / METSEPM2210 |
| Product Family |
Schneider Electric EasyLogic PM2200 series |
| Commercial Reference |
METSEPM2210 |
| Description |
EasyLogic PM2210, Power & Energy meter, Total Harmonic, display, pulse, Class 1 |
| Mounting |
Panel mount / flush mount, 96 mm × 96 mm format |
| Display |
Local panel display for electrical parameters |
| Active Energy Accuracy |
Class 1 active energy |
| Reactive Energy Accuracy |
Class 1 reactive energy |
| Current Input |
1A / 5A CT secondary input |
| Measured Voltage |
Up to 480V AC line-to-line, depending on installation configuration |
| Total Harmonic Distortion |
THD for voltage and current |
| Pulse Output |
1 pulse output for energy pulse collection |
| Pulse Inputs |
2 pulse inputs |
| Sampling Rate |
64 samples per cycle |
Measured Parameters
| Parameter Group |
Typical Values Measured |
| Voltage |
Line-to-line and line-to-neutral voltage values depending on wiring configuration. |
| Current |
Phase current values through 1A or 5A CT secondary inputs. |
| Power |
Active, reactive and apparent power for load monitoring. |
| Energy |
Active, reactive and apparent energy for panel metering and sub-metering. |
| Power Factor |
Power factor values for capacitor bank and reactive power review. |
| Frequency |
System frequency measurement. |
| Demand |
Demand current and demand power values for basic load review. |
| Power Quality |
Total harmonic distortion for current and voltage. |
Communication and Integration
The PM2210 is mainly positioned as a local display and pulse-output meter. For systems that require full digital data through RS485 Modbus or Ethernet, a communication-enabled EasyLogic or PowerLogic model should be selected.
| Integration Requirement |
PM2210 Capability |
| Local Panel Display |
Supported through the meter display. |
| Pulse-Based Energy Monitoring |
Supported through pulse output for external kWh counting. |
| Pulse Input |
2 pulse inputs available for pulse-related applications. |
| RS485 Modbus Monitoring |
Not the main function of this PM2210 model. Select a Modbus-enabled model if full register-based monitoring is required. |
| Ethernet Monitoring |
Not available on this PM2210 model. Select an Ethernet-enabled model if direct IP communication is required. |
| IoTWatt 4.0 |
Can be used for pulse-based kWh monitoring through a pulse input module or gateway. For full analytics, Modbus or Ethernet meters are recommended. |
Selection note: PM2210 is suitable for basic display and pulse-output metering. For IoTWatt 4.0 dashboards requiring live voltage, current, power factor, demand and harmonic data, consider a Modbus or Ethernet-enabled meter such as PM5110, PM5310, PM5320, PM5560 or equivalent.
Why Use EasyLogic PM2210?
The PM2210 is suitable when the project needs a cost-effective Schneider Electric panel power meter for local visibility, basic energy metering and pulse output. It is a practical option for many basic sub-metering points.
- Provides Class 1 active energy measurement for basic energy metering.
- Provides local display of voltage, current, power, energy, power factor and frequency.
- Supports total harmonic distortion visibility for voltage and current.
- Includes pulse output for external energy counting.
- Suitable for 96 mm × 96 mm panel meter applications.
- Useful for distribution boards, feeder panels, tenant sub-metering and panel upgrades.
- Suitable where simple metering is required without full digital communication.
Integration with IoTWatt 4.0
IoTWatt 4.0 can use PM2210 pulse output for basic kWh monitoring when connected to a suitable pulse input module or gateway. This is suitable for simple energy tracking where kWh data is sufficient.
- Use pulse output for basic kWh trend monitoring.
- Connect pulse output to a compatible pulse counter, PLC, I/O module or gateway.
- Use measured energy data for simple sub-metering and consumption tracking.
- For richer analytics, use Modbus or Ethernet meters to capture voltage, current, power, power factor, demand and harmonics.
Recommended Deployment Checklist
- Confirm the electrical system voltage and wiring configuration.
- Confirm CT secondary rating: 1A or 5A.
- Confirm CT ratio, CT class, CT burden and CT polarity.
- Confirm 96 mm × 96 mm panel cut-out and installation clearance.
- Confirm control power availability.
- Confirm pulse output requirement and pulse scaling.
- Confirm pulse counter, PLC, I/O module or gateway compatibility.
- Confirm whether only kWh pulse monitoring is sufficient or full digital monitoring is required.
- Test voltage phase sequence, CT direction, displayed readings and pulse output during commissioning.
EasyLogic PM2210 Supply, Commissioning and IoTWatt 4.0 Pulse Integration
Saturn Pyro supports Schneider Electric EasyLogic PM2210 meters for panel metering, sub-metering, pulse-based energy monitoring, distribution board metering, basic THD visibility and IoTWatt 4.0 energy monitoring projects in Malaysia.
Enquire Now
More detail about Saturn Pyro Sdn Bhd