Description
QEED Universal Temperature Converter
QA-TEMP Universal Temperature Converter
The QEED QA-TEMP is an advanced universal temperature converter for RTD, thermocouple, potentiometer and resistance measurement. It provides 4-way galvanic isolation, programmable analogue retransmission output, relay alarm output, RS485 Modbus RTU communication and USB datalogging.
The module is suitable for industrial temperature monitoring, process signal conversion, machine panels, BMS, EMS, SCADA, PLC, data logger and IoT applications where temperature or resistance signals must be isolated, converted, logged and transmitted digitally.
Inputs
RTD, TC, potentiometer and resistance
Outputs
0 20mA, 0 10V, relay and RS485
Isolation
4-way galvanic isolation
Datalogging
USB pen drive logging with RTC
Overview
QA-TEMP converts temperature, potentiometer or resistance input signals into standard industrial output formats. It can provide a programmable analogue output, alarm relay output and RS485 Modbus RTU data from one compact DIN rail module.
The built-in USB datalogging function allows site teams to record measurement data locally using a USB pen drive. Stored data can be downloaded in Excel-importable format for commissioning, troubleshooting, trending and reporting.
Positioning: Universal temperature and resistance converter with analogue retransmission, alarm relay, RS485 Modbus and USB datalogging.
Key Features
Universal Input
Supports RTD, thermocouple, potentiometer and resistance measurement from one module.
Programmable Output
Provides programmable current or voltage analogue output for retransmission to PLC, BMS or EMS.
Relay Alarm Output
5A SPDT relay contact can be configured for alarm or threshold output through software.
RS485 Modbus RTU
Communicates as a Modbus RTU slave through terminals or optional base module connection.
USB Datalogging
Logs data using USB On-The-Go and a pen drive, with integrated real-time clock.
DIN Rail Mounting
Compact 17.5mm module for control panels, BMS panels and industrial enclosures.
Supported Inputs
| Input Type |
Supported Signals |
Notes |
| RTD |
Pt100, Pt500, Pt1000, Ni100 |
2, 3 or 4 wire measurement with automatic cable interruption detection |
| Thermocouple |
Types J, K, R, S, T, B, E, N |
Automatic cable interruption detection |
| Potentiometer |
1000Ω to 10kΩ |
Suitable for position or resistance-based sensing applications |
| Resistance |
400Ω or 4000Ω range |
2, 3 or 4 wire resistance measurement |
Output Functions
| Output |
Specification |
Typical Use |
| Current Output |
0 20mA programmable, maximum load resistance 600Ω |
Retransmission to PLC, controller, BMS, EMS or recorder |
| Voltage Output |
0 10V programmable, minimum load resistance 2kΩ |
Retransmission to analogue input systems |
| Contact Alarm |
5A / 230Vac SPDT relay, fully programmable by FACILE QA-TEMP |
Alarm, threshold output or control interlock |
| RS485 Modbus |
RS485 Modbus RTU slave on terminals or optional base adapter |
SCADA, PLC, EMS, BMS, IoT gateway and IoTWatt 4.0 integration |
4-Way Isolation
QA-TEMP provides 4-way galvanic isolation between the input, analogue / digital output, RS485 / USB communication and power supply. This is useful in industrial environments where signal noise, ground loops and different reference potentials can affect measurement quality.
Isolation paths: Input, analogue and digital output, RS485 / USB communication and power supply are galvanically isolated at 1.5kV.
Datalogging Function
The QA-TEMP can log data through the USB On-The-Go port using a USB pen drive. The integrated RTC real-time clock allows timestamped records, and stored data can be downloaded in Excel-importable format.
- USB pen drive data logging
- Integrated RTC real-time clock
- Excel-importable stored data files
- Useful for site commissioning and troubleshooting
- Suitable for temporary temperature trending and performance checks
Technical Specifications
| Parameter |
Specification |
| Power Supply |
10 to 40Vdc or 20 to 28Vac, 50/60Hz |
| Input |
RTD, thermocouple, potentiometer or resistance input |
| Retransmission Output |
Isolated analogue output, programmable voltage or impressed current; active or passive output supply |
| Sensor Power Supply |
13Vdc, 30mA max |
| Absorption |
Maximum 2VA |
| Protection Index |
IP20 |
| Accuracy |
0.1% F.S. |
| Resolution |
16-bit |
| Rejection |
50 60Hz |
| Thermal Stability at 25°C |
<100ppm / °C |
| Working Temperature |
-15°C to +65°C |
| Storage Temperature |
-40°C to +85°C |
| Isolation |
Input, analogue / digital output, RS485 / USB and power supply isolated at 1.5kV |
| Humidity |
10% to 90%, non-condensing |
| Altitude |
Up to 2000m a.s.l. |
| Mounting |
DIN rail mounting with removable terminals; optional base connection for RS485 bus and supply |
| Connections |
Removable 5.08mm terminals |
| CE Standards |
EN61000-6-4:2006 + A1:2011; EN61000-6-2:2005; EN61010-1:2010 |
| Dimensions |
17.5 x 100 x 112mm, terminals excluded |
| Datalogger |
Non-volatile memory, USB On-The-Go logging with pen drive, Excel-importable file output, integrated RTC |
| Configuration |
FACILE QA-TEMP software via USB or RS485; DIP switch for Modbus address and baud rate |
Correction note: The old page referenced FACILE QA-VI in some datalogger/configuration rows. This updated page uses FACILE QA-TEMP because the product is QA-TEMP.
Typical Applications
Temperature Monitoring
Convert RTD or thermocouple signals for industrial temperature monitoring and control.
PLC / SCADA Integration
Send temperature values through analogue output, relay alarm or RS485 Modbus RTU.
BMS and EMS Panels
Use in building and energy management panels for temperature and process signal monitoring.
Machine and Process Systems
Convert sensor signals in machine tools, process skids and control panels.
Temporary Logging
Use USB datalogging for commissioning, troubleshooting and temperature trend studies.
IoTWatt 4.0
Can be integrated via RS485 Modbus or compatible input modules into IoTWatt 4.0 systems.
Configuration
QA-TEMP can be configured using the free FACILE QA-TEMP software through USB or RS485. The software allows configuration of input type, conversion range, span, zero, analogue output, relay alarm, logging and Modbus communication settings.
- Select RTD, thermocouple, potentiometer or resistance input
- Configure analogue output type and scaling
- Set span and zero
- Set relay alarm threshold and alarm behaviour
- Configure Modbus address and baud rate
- Configure USB datalogging interval and data storage
- Use DIP switches for basic Modbus address and baud rate settings
Commissioning note: Confirm sensor type, wiring method, input range, output scaling and Modbus parameters before connecting the converter to a live monitoring or control system.
System Integration
QA-TEMP is suitable for temperature and resistance signal integration into PLC, SCADA, BMS, EMS, data logger, Modbus gateway and IoTWatt 4.0. Its combination of analogue output, relay alarm, RS485 Modbus and USB datalogging makes it useful for both permanent installations and temporary troubleshooting.
- Use analogue output for direct PLC or controller input
- Use relay output for alarm or threshold indication
- Use RS485 Modbus RTU for digital monitoring
- Use USB datalogging for site temperature trend capture
- Use optional base connection for cleaner multi-module panel wiring
QA-TEMP Supply and Integration
Saturn Pyro supports QEED QA-TEMP universal temperature converters for RTD, thermocouple, potentiometer, resistance measurement, signal isolation, analogue retransmission, relay alarm, RS485 Modbus integration, USB datalogging, PLC, SCADA, BMS, EMS and IoTWatt 4.0 projects in Malaysia.
Enquire Now
More detail about Saturn Pyro Sdn Bhd