Archmeter PA30 Compact Smart Meter

PA30 Series Compact Smart Meter

The Archmeter PA30 Series is a compact rail-mounted smart meter range designed for general single-phase and poly-phase power measurement. It is suitable for low-voltage primary-side metering and medium / high-voltage secondary-side metering when used with the correct CT and wiring arrangement.

The PA30 Series includes the PA34 for 1-phase 4-channel monitoring and the PA33 for three-phase power monitoring. With clip-on CTs, RS485 Modbus communication, compact size, low auxiliary power requirement and kWh accuracy better than 0.5% at PF = 1, the PA30 is suitable for retrofit metering, feeder monitoring, panel monitoring and energy management applications.

Meter Series PA30 Compact Smart Meter
Models PA34: 1-phase 4-channel / PA33: 3-phase
CT Options Ø10 mm 60A, Ø16 mm 100A, Ø24 mm 200A
Communication RS485 Modbus, optional LonTalk

Product Description

The PA30 Series is designed for compact power and energy measurement in existing or new electrical panels. Its clip-on CT design makes installation easier for retrofit applications because the CTs can be installed around existing conductors with reduced wiring effort.

The PA34 model is designed for 1-phase 4-channel monitoring, making it useful for multiple single-phase circuits. The PA33 model is designed for three-phase applications and supports multiple wiring modes, including 1P2W, 1P3W, 3P3W and 3P4W configurations.

Best use case: PA30 is suitable where compact DIN rail metering is required with clip-on CTs, RS485 Modbus communication and multiple circuit / phase measurement from a small device.

Key Features

Compact Rail-Mounted Design

Small 78 mm × 35 mm × 99 mm body size suitable for crowded electrical panels and retrofit metering cabinets.

Clip-On CT Installation

Clip-on CTs make wiring simpler and help reduce installation work in existing panels.

Wide CT Range

Supports CT Ø10 mm 60A, CT Ø16 mm 100A and CT Ø24 mm 200A measurement options.

True RMS Measurement

Measures True RMS power and energy parameters in a compact smart meter format.

kWh Accuracy Better Than 0.5%

Provides kWh accuracy of 0.5% at PF = 1, better than IEC 62053-21 requirements.

RS485 Modbus Communication

Built-in half-duplex isolated RS485 communication supports Modbus protocol for integration with gateways and monitoring systems.

Optional LonTalk Port

Optional LonTalk secondary communication port is available for projects requiring LonWorks-type integration.

Low DC Auxiliary Power

Operates with DC 10–30V auxiliary power, useful for compact metering panels and gateway systems.

Single-Phase or Three-Phase Use

PA34 supports 1-phase 4-channel monitoring, while PA33 supports three-phase wiring configurations.

PA33 and PA34 Model Selection

Model Application Input Voltage Wiring / Channel Configuration Recommended Use
PA34 1-phase 4-channel compact smart meter 10–300V 1-phase 4-channel Multiple single-phase loads, tenant circuits, lighting circuits, small power circuits and distributed sub-metering.
PA33 Three-phase compact smart meter 10–500V Auto or manual setting: 1P2W-1CT, 1P3W-2CT, 3P3W-2CT, 3P3W-3CT and 3P4W. Three-phase feeders, motors, pumps, HVAC panels, distribution boards and energy monitoring applications.
Selection note: Use PA34 when the requirement is to monitor up to four single-phase circuits. Use PA33 when the requirement is to monitor a three-phase feeder or a poly-phase electrical system.

Ordering Code Structure

The PA30 ordering code is based on the meter model, CT size and secondary communication port option.

Ordering Code Field Available Option Description
Model 4 PA34: 1-phase 4-channel model.
Model 3 PA33: 3-phase model.
CT Size 0 CT Ø10 mm, standard, 60A.
CT Size 1 CT Ø16 mm, optional, 100A.
CT Size 2 CT Ø24 mm, optional, 200A.
Secondary Communication Port 0 No secondary communication port.
Secondary Communication Port 1 LonTalk secondary communication port option.
Ordering example: PA3x ---- x x structure means the final selection must confirm the model type, CT size and secondary communication-port option before ordering.

Size and Latch

The PA30 Series has a compact rail-mounted enclosure, making it suitable for installation inside distribution boards, control panels, metering panels and IoT gateway panels.

PA30 Compact Smart Meter size and latch drawing

PA30 Size and Latch

Technical Specification

Item Specification
Input Voltage PA34: 10–300V. PA33: 10–500V.
Input Current Clip-on CT Ø10 mm 60A, CT Ø16 mm 100A and CT Ø24 mm 200A.
Auxiliary Power DC 10–30V.
Frequency 50 / 60 Hz.
Starting Current < 0.001 Ib.
Wiring Diagram PA34: 1-phase 4-channel. PA33: auto or manual setting for 1P2W-1CT, 1P3W-2CT, 3P3W-2CT, 3P3W-3CT and 3P4W.
Communication RS485, half-duplex isolated. Baud rate: 9600, 19200 default and 38400. Protocol: Modbus. LonTalk optional.
kWh Accuracy 0.5% at PF = 1, better than IEC 62053-21.
Size 78 mm (L) × 35 mm (W) × 99 mm (H).
Operating Temperature -10°C to 60°C.
Installation Rail-mounted.

Measured Parameters

Model Measured Parameters
PA34 V1, V2, I1, I2, I3, I4, kW1–kW4, kVA1–kVA4, kvar1–kvar4, PF1–PF4, kWh1–kWh4, kVAh1–kVAh4 and kvarh1–kvarh4.
PA33 VA, VB, VC, Vave, IA, IB, IC, Iave, kWA, kWB, kWC, kWtot, kVAA, kVAB, kVAC, kVAtot, kvarA, kvarB, kvarC, kvartot, PFA, PFB, PFC, PFtot, kWhA, kWhB, kWhC, kWhtot, kVAhA, kVAhB, kVAhC, kVAhtot, kvarhA, kvarhB, kvarhC and kvarhtot.

Certification and Compliance

The PA30 datasheet lists LVD, CE and FCC test compliance. This supports use in industrial and commercial environments where EMC and safety compliance are required.

Test / Standard Listed Compliance
LVD Test EN 61010-1.
CE Conducted / Radiated Emission EN 61326 conducted emission and EN 61326 radiated emission.
CE Immunity / EMC Tests EN 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8 and EN 61000-4-11.
FCC Test Class A and CISPR 22.

Typical Applications

Retrofit Sub-Metering

Clip-on CTs make the PA30 suitable for adding metering to existing panels and feeders.

Single-Phase Circuit Monitoring

PA34 can monitor multiple single-phase channels from one compact meter.

Three-Phase Feeder Monitoring

PA33 supports three-phase feeder monitoring with flexible wiring modes.

Tenant and Floor Metering

Use PA30 for energy allocation by tenant, floor, area or department.

Equipment-Level Energy Monitoring

Monitor HVAC, pumps, lighting panels, small power circuits and production loads.

EMS / BMS / SCADA Integration

RS485 Modbus allows integration with monitoring systems, gateways and IoTWatt 4.0.

Typical System Integration

PA30 meters can be installed inside metering panels or distribution boards. Measurement data can be collected through RS485 Modbus and connected to a gateway, BMS, EMS, SCADA or IoTWatt 4.0 for centralised monitoring and reporting.

Integration with IoTWatt 4.0

When connected to IoTWatt 4.0, PA30 meter data can be used for energy dashboards, circuit comparison, tenant metering, feeder-level analytics, digital energy audit, EECA reporting support and abnormal energy consumption detection.

  • Monitor single-phase or three-phase energy values through RS485 Modbus.
  • Use PA34 for multiple single-phase circuit monitoring.
  • Use PA33 for three-phase feeder and equipment monitoring.
  • Collect kWh, kW, kVA, kvar, PF and related measured values for dashboards and reports.
  • Use circuit-level data for baseline creation, load profiling and energy audit evidence.
  • Connect through RS485 using a suitable gateway such as RS2LAN, RS2MQTT or RS2WLAN.
Integration note: PA30 is a practical compact smart meter for IoTWatt 4.0 projects where retrofit-friendly CT installation and Modbus data collection are required.

Recommended Deployment Checklist

  • Confirm model selection: PA34 for 1-phase 4-channel or PA33 for three-phase monitoring.
  • Confirm CT size: Ø10 mm 60A, Ø16 mm 100A or Ø24 mm 200A.
  • Confirm whether optional LonTalk secondary communication port is required.
  • Confirm auxiliary power availability: DC 10–30V.
  • Confirm wiring mode and phase configuration.
  • Confirm RS485 address, baud rate, parity, shielding and termination.
  • Confirm panel rail space and CT installation clearance.
  • Confirm EMS, BMS, SCADA, gateway or IoTWatt 4.0 integration requirement.
  • Test CT direction, voltage reference, phase mapping and Modbus communication during commissioning.

PA30 Smart Meter Supply, Commissioning and IoTWatt 4.0 Integration

Saturn Pyro supports Archmeter PA30 Compact Smart Meters for retrofit sub-metering, PA33 three-phase metering, PA34 single-phase 4-channel metering, RS485 Modbus integration, EMS / BMS / SCADA connectivity and IoTWatt 4.0 digital energy audit projects in Malaysia.

Enquire Now

More detail about Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd Energy Meters Supplier Johor Bahru (JB), Energy Management Malaysia, Selangor, Power Quality Analyzers Supply Kuala Lumpur (KL), Penang ~ Saturn Pyro Sdn Bhd
Contact Us flagMalaysia