Fluke 414D Laser Distance Meter
												 
												
													
														
															| Distance Measurement | 
														 
														
															| Typical Measuring Tolerance[1] | 
															± 2.0 mm [3] | 
														 
														
															| Maximum Measuring Tolerance[2] | 
															± 3.0 mm [3] | 
														 
														
															| Range at Leica target plate GZM26 | 
															50 m / 165 ft | 
														 
														
															| Typical Range[1] | 
															40 m / 130 ft | 
														 
														
															| Range at unfavorable condition[4] | 
															35 m / 115 ft | 
														 
														
															| Smallest unit displayed | 
															1 mm / 1/16 in | 
														 
														
															| ∅ laser point at distances | 
															6 /30 / 60 mm  
															(10 / 50 / 100 m) | 
														 
														
															| Tilt measurement | 
														 
														
															| Measuring tolerance to laser beam[5] | 
															No | 
														 
														
															| Measuring tolerance to housing[5] | 
															No | 
														 
														
															| Range | 
															No | 
														 
														
															| General | 
														 
														
															| Laser class | 
															2 | 
														 
														
															| Laser type | 
															635 nm, <1 mW | 
														 
														
															| Protection class | 
															IP40 | 
														 
														
															| Automatic laser off | 
															After 90 seconds | 
														 
														
															| Automatic power off | 
															after 180 seconds | 
														 
														
															| Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 | 
															Up to 3,000  
															measurements | 
														 
														
															| Size (H X W X L) | 
															116mm Length 
															53mm Width  
															33mm Depth | 
														 
														
															| Weight (with batteries) | 
															113 g | 
														 
														
															| Temperature range: Storage Operation | 
															-25 °C to +70°C 
															(-13 °F to +158 °F)  
															 
															0 °C to +40 °C  
															(32 °F to +104 °F) | 
														 
														
															| Calibration cycle | 
															Not applicable | 
														 
														
															| Maximum altitude | 
															3000 m | 
														 
														
															| Maximum relative humidity | 
															85% at 20 °F to 120°F  
															(-7 °C to 50 °C) | 
														 
														
															| Safety | 
															IEC Standard No. 61010-1:2001  
															EN60825-1:2007 (Class II) | 
														 
														
															| EMC | 
															EN 55022:2010 
															EN 61000-4-3:2010 
															EN 61000-4-8:2010 | 
														 
														
															[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.  
															[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C. 
															[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m. 
															[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux. 
															[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. | 
														 
													
												 
												 
												Fluke 62 MAX+ Infrared Thermometer
												 
												
													
														
															| Specifications | 
														 
														
															| 
															 Temperature Range 
															 | 
															-30 °C to 650 °C (-22 °F to 1202 °F) | 
														 
														
															| Accuracy | 
															±1.0 °C or ±1.0% of reading, whichever is greater 
															-10 °C to 0 °C: ±2.0 
															-30 °C to -10 °C: ±3.0 | 
														 
														
															| Response Time (95%) | 
															Fluke 62 MAX+ | 
															<300 ms (95% of reading) | 
														 
														
															| Spectral Response | 
															8 to 14 microns | 
														 
														
															| Emissivity | 
															0.10 to 1.00 | 
														 
														
															| 
															 Optical Resolution 
															 | 
															12:1 (calculated at 90% energy) | 
														 
														
															| Display Resolution | 
															0.1 °C (0.2 °F) | 
														 
														
															| Repeatability of Readings | 
															±0.5% of reading or <±0.5 °C (1 °F), whichever is greater | 
														 
														
															| Power | 
															AA battery | 
														 
														
															| Battery Life | 
															8 hours with laser and backlight on | 
														 
														
															| Physical Specifications | 
															Weight | 
															255 g (8.99 oz) | 
														 
														
															|   | 
															Size | 
															(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | 
														 
														
															|   | 
															Operating Temperature | 
															0 °C to 50 °C (32 °F to 122 °F) | 
														 
														
															|   | 
															Storage Temperature | 
															-20 °C to 60 °C (-4 °F to 140 °F), (without battery) | 
														 
														
															|   | 
															Operating Humidity | 
															10 % to 90 % RH non-condensing at 30 °C (86 °F) | 
														 
														
															|   | 
															Operating Altitude | 
															2000 meters above mean sea level | 
														 
														
															|   | 
															Storage Altitude | 
															12,000 meters above mean sea level | 
														 
														
															|   | 
															IP Rating | 
															IP 54 per IEC 60529 | 
														 
														
															|   | 
															Drop Test | 
															3 meters | 
														 
														
															|   | 
															Vibration and Shock | 
															IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | 
														 
														
															|   | 
															EMC | 
															EN 61326-1:2006 EN 61326-2:2006 | 
														 
														
															| 
															 Standards and Agency Approval 
															 | 
															Compliance | 
															 EN/IEC 61010-1: 2001 | 
														 
														
															|   | 
															Laser Safety | 
															FDA and EN 60825-1 Class II | 
														 
													
												 
												 | 
											 
										
									 
									 
									 
									 
									 
									 | 
								 
							
						 
						 | 
						  |