Office Air Vents

Kategori: AHU Ducting & Terminal Connection Setup Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di eakon.com.my

Penerangan

AHU Ducting & Terminal Connection Setup: Office Air Vents

In the 2026 Malaysian corporate landscape, Office Air Vents (comprising supply diffusers and return grilles) are the final engineering interface of the ventilation system. Governed by MS 1525:2024 and the Energy Efficiency and Conservation Act (EECA) 2024, these vents are responsible for delivering the energy savings generated by your VFD-driven AHU directly to the occupants without creating noise or drafts.

At EKG (Malaysia) SDN BHD, we engineer air vent installations to be Sterile, Silent, and Statutory-Compliant, ensuring your workspace supports both high productivity and mandatory building energy targets.


1. Types of Office Air Vents & Their Roles

The selection of a vent is dictated by the ceiling height, the layout of the workstations, and the thermal load of the office zone.

Vent Type Pattern / Feature Best Application
4-Way Square Diffuser 360° horizontal throw Open-plan offices; maximizes air mixing and prevents "Cold Dumping."
Linear Slot Diffuser Sleek, narrow profile Executive boardrooms and glass perimeters; provides a "curtain" of air.
Swirl Diffuser High-induction vortex High-occupancy zones; mixes cool air rapidly to eliminate hot spots.
Return Air Grille High free-area mesh Located in corridors or central zones to draw air back to the AHU.

2. Statutory Framework: IAQ & Acoustic Comfort

Under DOSH 2026 and MS 1525:2024, office air vents must meet strict performance metrics to pass a mandatory building audit.


3. Installation Engineering: The Terminal Setup

A professional EKG installation ensures that the vent is correctly interfaced with the Acoustic Sound-Attenuated Ducting.

  1. Cushion Head Plenum (CHP): Every supply vent is paired with a plenum box. This box allows the high-velocity air from the duct to expand and equalize pressure, ensuring a uniform throw from all sides of the vent.

  2. Insulated Flexible Connection: We utilize R-6.0 insulated flexible ducting to connect the main branch to the vent. This connection is kept between 1.5 to 2.0 meters to minimize friction and prevent "sweating" in KL’s humidity.

  3. Vibration Isolation: Vents are securely anchored to the ceiling grid using vibration-isolated supports to prevent the transmission of mechanical "hum" from the VFD-driven fan.


4. The "Fire Mode" Statutory Protocol

Office air vents must comply with BOMBA (JBPM) 2026 fire compartmentation standards, particularly regarding fire-rated ceilings.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your office air vent setup causing distracting noise or uneven cooling?

Contact EKG (Malaysia) SDN BHD today for a specialized Office Airflow & Acoustic Audit.