LINSHANG LS330 Spectral Illuminance Meter

LINSHANG LS330 Spectral Illuminance Meter

Kategori: Testing Instruments Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di mtmpre.com.my

Penerangan

LS330 Spectral Illuminance Meter

Measurement of Lux, CCT, UVI and other parameters

Multi-mode, multi-parameter measurement for broader applications
Equipped with plant mode,accurately detect PPFD
1,000,000Lux ultra-large range design
High precision, pass authoritative metrology inspection


LS330 spectral Illuminance Meter is a versatile instrument designed with a spectral sensor. It is used for measuring illuminance, UV index, flicker frequency, standard deviation of color matching (SDCM), color rendering index (CRI), correlated color temperature (CCT), blue light hazard ratio, temperature, and humidity in various scenarios such as lamps and lanterns lighting, outdoor lighting, greenhouse lighting, and stage lighting. The instrument also can display the spectral curve, which helps identify the type of lighting fixture.The instrument also has a plant illumination mode, which is specially designed for plant growth environments. It can accurately measurephotosynthetic photon flux density(PPFD), PPFD (Blue), PPFD (Green), PPFD (Red), Yield Photon Flux Density (YPFD), chlorophyll-a, and chlorophyll-b, helping users understand and optimize light management during the planting process and improve plant growth efficiency. It is suitable for home gardening, plant factories, greenhouses, agricultural research, plant lighting, and other fields.

Lighting design and evaluation
 
lighting fixture manufacturing and sales
 
film production and photography
 
plant grow light optimization
 
ambient light monitoring
 
medical and scientific research
 

LS330 Five Major Features

 

Parameters

Parameters Value
Illuminance Wavelength Range 400nm ~ 700nm
Illuminance Wavelength Interval 10nm
Illuminance Measurement Range 0 ~ 1000000Lux
Illuminance Resolution 0.1Lux
Illuminance Measurement Accuracy ≤±(3%H + 2 Lux) (H is the standard value, calibrated under CIE standard A light source)
Illuminance Unit Options Lux (default), FC
Correlated Color Temperature Measurement Range 1000 ~ 100000K
UV Index Measurement Range 0.0 ~ 15.0
Flicker Frequency Measurement Range 10 ~ 500HZ
Temperature Measurement Accuracy ±0.5℃
Humidity Measurement Accuracy ±4%RH
PPFD measurement range 0 – 10000 μmol/m²/s
PPFD measurement accuracy ≤±(5%H+0.5 μmol/m²/s)
PPFD (Blue) measurement range 0 – 5000 μmol/m²/s
PPFD (Blue) measurement accuracy ≤±(10%H+0.5 μmol/m²/s)
PPFD (Green) measurement range 0 – 5000 μmol/m²/s
PPFD (Green) measurement accuracy ≤±(10%H+0.5 μmol /m²/s)
PPFD (Red) measurement range 0 – 5000 μmol/m²/s
PPFD (Red) measurement accuracy ≤±(10%H+0.5 μmol /m²/s)
YPFD measurement range 0 – 10000 μmol/m²/s
YPFD measurement accuracy ≤±(5%H+0.5 μmol /m²/s)
Chlorophyll-a measurement range 0 – 10000μW/cm²
Chlorophyll-a measurement accuracy 1.≤±(10%H+0.5μW/cm²)
Chlorophyll-b measurement range 0 – 10000μW/cm²
Chlorophyll-b measurement accuracy ≤±(10%H+0.5μW/cm²)
Response Time <0.7s
Test Aperture Diameter Φ21mm
Size Length 188.5mm Width 75.2mm Height 30.3mm
Weight About 232g (including batteries)
Display 240*160 Dot Matrix LCD
Power Supply 2 AA Alkaline Batteries
Operating Environment Temperature 0 ~ 40℃, Humidity <85%RH

Features

 
 

Multi-parameter, wider application

In normal mode, the instrument measures parameters like illumination, CCT, flicker frequency, UV index, SDCM, CRI, temperature, and humidity to evaluate lighting characteristics. In plant mode, it accurately measures PPFD, YPFD, chlorophyll-a, and chlorophyll-b to optimize plant lighting for better quality and yield.

 

Greenhouse Lighting Measurement
 
Street Lighting Measurement
 
Nursery Lighting Measurement
 
Desk Lamp Measurement
 

Freely switch between normal and plant modes

The instrument offers both normal and plant illumination modes, meeting diverse measurement needs. It handles both everyday lighting detection and plant growth parameters (e.g., PPFD, chlorophyll content), helping users optimize lighting in various scenarios.

 

 
 

High-precision spectral sensors

The instrument is designed with a spectral sensor, and the spectral response matches the V(λ) function. This ensures accurate measurement precision.

 

LS330 spectral response
 

Spectral curve measurement

The instrument has a spectral curve measurement function, which can view the light intensity and distribution at different wavelengths, identify whether the light source has spectral missing and detect whether it has blue light protection.

 

1 million Lux measurement range, suitable for both strong and dim light

Ultra-large range design, range up to 1 million Lux, both strong and dim light can be measured accurately.

 

 

Flicker measurement, easily determine if lighting meets requirements

The instrument features a flicker measurement function, can evaluate whether lighting meets requirements based on flicker frequency and percent flicker. This provides reference for sales and R&amp;D of lighting.

 

Flicker measurement
 

Measurement of CCT

The instrument measures correlated color temperature, aiding lighting manufacturers in fixture development and lighting design.

 

CRI and CDCM measurement

The instrument has CRI and SDCM measurement function, clearly showing the difference between the testing light source and the standard light source.

 

CRI and CDCM measurement

Display blue light hazard ratio

The blue light hazard ratio can be displayed to objectively evaluate the blue light hazard of the lighting source.
(The blue light hazard ratio is the ratio of the blue light hazard to the corresponding radiation amount. The larger the ratio, the greater the proportion of blue light.)

 

 

Accurately measure photosynthetic photon flux density (PPFD)

The instrument can accurately measure photosynthetic photon flux density (PPFD), yield photon flux density (YPFD) and chlorophyll content, providing comprehensive data support to help optimize plant light intensity, distribution and health status, and improve growth and yield.

 

Accurately measure photosynthetic photon flux density (PPFD)

Lebih maklumat tentang MTM Precision Sdn Bhd
MTM Precision Sdn Bhd
MTM Precision Sdn Bhd Surveying Instruments Selangor, GPS Systems Supply Kuala Lumpur (KL), Total Stations Supplier Malaysia ~ MTM Precision Sdn Bhd