AC current measurement image
After removing the clamp sensor coil at the joint, clamp the object to be measured.
LED light function brightly illuminates the object being measured
Equipped with a backlight LCD for easy viewing even in dark places| range | resolution | Accuracy | frequency | |
|---|---|---|---|---|
| ACA | 0.2 to 10 A | 0.01 A | ±(2.0% rdg + 10 dgt) | 40 to 65 Hz |
| 10 to 60 A | 0.01 A | ±(1.5% rdg + 5 dgt) | ||
| 60 to 600 A | 0.1 A | |||
| 600 to 3000 A | 1 A | ±(2.0% rdg + 5 dgt) | ||
| 0.2 to 60 A | 0.01 A | ±(2.5% rdg + 5 dgt) | 65 to 200 Hz | |
| 60 to 600 A | 0.1 A | |||
| 600 to 3000 A | 1 A | ±(3.0% rdg + 5 dgt) | ||
| 0.2 to 60 A | 0.01 A | ±(3.0% rdg + 5 dgt) | 200 Hz to 1 kHz | |
| 60 to 600 A | 0.1 A | |||
| 600 to 1000 A | 1 A | |||
| frequency | 40 to 1000 Hz | 0.1 Hz | ±(0.5 % rdg + 2 dgt) at 3 A or more | - |
| Distance from center | Addition to accuracy | |
|---|---|---|
| A | Radius 35 mm (Φ70) | ±0.5% |
| B | Radius 50 mm (Φ100) | ±1.5% |
| C | Radius 60 mm (Φ120) | ±2.0% |
| D | Radius 60 mm (Φ120) or more | ±5.0% |
| Detection method | True RMS |
|---|---|
| display | LCD display, 6000 counts |
| Range switching | Auto |
| Maximum measurement conductor diameter | φ120 mm |
| sampling | Approximately 3 times/second |
| Auto Power Off | Approximately 5 minutes (cannot be canceled) |
| Operating temperature and humidity | 0 to +40°C, 80% RH or less (no condensation) |
| Storage temperature and humidity | -10 to +60°C, 80% RH or less (excluding batteries, no condensation) |
| size | Approx. W 178 × H 324 × D 30 mm |
| weight | Approximately 188 g (including batteries) |
| power supply | 3 x AAA batteries |
| battery life | Up to approximately 70 hours (when using alkaline batteries) *3 |
| accessories | Storage case, instruction manual |
| proofreading | Possible |
| Compliance standards | EN61010-1, EN61010-2-032, EN61326-1 CAT III 1000V, CATIV 600V |
| JAN | 4983621090239 |
Malaysia