| Compatible case size | PS2- | |
| Outline drawing | 150Wx86Hx120D | |
| Weight | 1.60 kg typ | |
| Input Voltage | AC | 85-264V |
| Efficiency | AC | 68% typical at AC 100V and 71% typical at AC 240V |
| Power factor | 98% typical at AC 100V, and 92% typical at AC 240V | |
| Input changeover system | Worldwide | |
| Safety | UL60950, CSA-60950,CE marking(IEC62368-1) | |
| High frequency current regulation | Compliant with IEC61000-3-2(Ed. 2.1) Class D | |
| EMI standard (Input feedback noise) |
Compliant with VCCI Class B FCC Rules Class B and EN55022 Class B | |
| CE marking | Low voltage and EMI directive and RoHS2.0 | |
| EMS immunity | Electrostatic discharge to meet EN61000-4-2 Radioactive radio-frequency electromagnetic fields to meet EN61000-4-3 Fast transient burst to meet EN61000-4-4 Lightning surge immunity to meet EN61000-4-5 Conducted radio-frequency electromagnetic fields to meet EN61000-4-6 Power frequency magnetic field immunity to meet EN61000-4-8 Voltage dips and fluctuation to meet EN61000-4-11 |
|
| MTBF | 130,000H | |
| Operating temperature | 0 to 50 deg. C. | |
| Leakage current | 0.5mA max. at AC 100V and 1mA max. at AC 240V | |
| Cooling systems | Forced air cooling | |