Features
•Best for scale, to 6000 div, (at the input of 2.0 micro-V/d or more)
•Measurement value display with large-scale fluorescent display 22mm character height.
•Full six digit (999 999) can be displayed.
•Unit (t,kg,g,lb) displayed.
•Build-in linear riser (three points or less)
•Weigh-in/ weigh-out mode
•Multiple I/O functions
Serial interface, BCD, RS-232C, RS-422/485, 0~10V, 4~20mA
•Protection grade: IP65
Specification
| Specification name | Specification contents |
| Bridge power supply | 5 VDC±0.25VDC 120 mA with sensing function |
| Input sensitivity | 0.2μV/dor more (d= minimum scale) |
| Input range | -3.1 mV/V ~ 3.1mV/V |
| Zero adjustment range | -2.5mV/V ~ 2.5mV/V |
| Non-linearity | 0.01% F.S |
| Temperature effect | Zero point ±0.2μV/°C. Sensitivity ±0.0015%F.S./°C (during a calibration at the input sentivity 0.2micro-V/d or more |
| Load display | Display gross weightor Net weight |
| A/D sampling speed | 15 times/s |
| Display range | -999 999 ~ 999 999 |
| Condition display | ACCUM, MD, PT, TARE, GROSS, NET, ZERO |
| Judgement display | HI, OK, LO (OK: Green fluorescent display tube, HI/LO: Orangefluorescent display tube) |
| Display times | 5 times/s (Changeable to 15 times/s) |
| Decimal point display | Changeable to No display, 10¹, 10² or 10³ |
| Unit display | Changeable to g, kg,t or lb (Green fluorescent display tube) |
| Operating temp./ humidity range | Temperature -10°C ~ 40°C, Humidity 85%RH or less (Non condesing) |
| Power supply voltage | 100 VAC (85 VAC~110 VAC) 50/60 Hz |
| Power Consumption | Approx. 4VA |
| Outline Dimensions (WxHxD) |
192mm x 96mm x 165mm (excludes protruding parts) |
| Weight | Approx. 1.6kg (without options) |
| Protection code | IP65 or equivalent (Only for the fron panel when the attached panel mounting gascket is installed |