•Power for eight 350 load cells
•1 code; FINAL / SP1 / SP2 / FF / HI / Lo or LL / LO / OK / HI / HH.
•Automatic Free Fall Compensation.
•Standard: 20mA Current Loop and OP-02A1 RS-232
Specifications
•General
| Type |
BDI-2001B |
| Power Requirements |
AC 110V or AC 220V ±10% , 50 / 60Hz , Approx. 17VA |
| Net weight |
Approx. 3.2 kg (7.054 lb) |
| Operation Temperature |
-10°C ~ 45°C |
| Maximum Humidity |
85% (non-condensing) |
| Physical Dimension |
248 (D) x 190 (W) x 104 (H) mm |
•Analog Input and A/D Conversion
| Type |
BDI-2001B |
| Input Sensitivity |
>0.3uV/D |
| Zero Adjustment Range |
0~20mV |
| Load Cell Excitation |
DC12V±5%, 280mA, Remote Sensing. Can be connected up to 8 350Ω Load Cells |
| Non-Linearity |
0.01 % FS |
| A/D Conversion Method |
ΔΣ |
| A/D Resolution |
"R 1/500,000 |
| A/D Conversion Rate |
Approx. 30 Times / Sec. |
| Max. Load Cell Input Voltage |
36mV |
| ZERO Temperature Comp. |
±(0.2µV + 0.001% of Dead Load)/°C TYP |
| SPAN Temperature Comp. |
±0.001% °C TYP |
| Max. Resolution |
1/30,000 |