Circuit breaker size S00 for motor protection, CLASS 10 A-release 2.8...4 A N release 52 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC

Circuit breaker size S00 for motor protection, CLASS 10 A-release 2.8...4 A N release 52 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC

Kategori: SIMATIC Control Systems Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di geasb.com

Penerangan

product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss [W] for rated value of the current  
● at AC in hot operating state 7.25 W
● at AC in hot operating state per pole 2.4 W
insulation voltage with degree of pollution 3 at AC rated value 690 V
surge voltage resistance rated value 6 kV
mechanical service life (operating cycles)  
● of the main contacts typical 100 000
● of auxiliary contacts typical 100 000
electrical endurance (operating cycles) typical 100 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (Date) 01/01/2013
SVHC substance name Lead - 7439-92-1
Weight 0.288 kg
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature  
● during operation -20 ... +60 °C
● during storage -50 ... +80 °C
● during transport -50 ... +80 °C
relative humidity during operation 10 ... 95 %
Main circuit
number of poles for main current circuit 3
adjustable current response value current of the current-dependent overload release 2.8 ... 4 A
type of voltage for main current circuit AC
operating voltage  
● rated value 20 ... 690 V
● at AC-3 rated value maximum 690 V
● at AC-3e rated value maximum 690 V
operating frequency rated value 50 ... 60 Hz
operational current rated value 4 A
operational current  
● at AC-3 at 400 V rated value 4 A
● at AC-3e at 400 V rated value 4 A
operating power  
● at AC-3  
— at 230 V rated value 0.75 kW
— at 400 V rated value 1.5 kW
— at 500 V rated value 2.2 kW
— at 690 V rated value 3 kW
● at AC-3e  
— at 230 V rated value 0.75 kW
— at 400 V rated value 1.5 kW
— at 500 V rated value 2.2 kW
— at 690 V rated value 3 kW
operating frequency  
● at AC-3 maximum 15 1/h
● at AC-3e maximum 15 1/h
Auxiliary circuit
design of the auxiliary switch transverse
type of voltage for auxiliary and control circuit AC/DC
number of NC contacts for auxiliary contacts 1
number of NO contacts for auxiliary contacts 1
number of CO contacts for auxiliary contacts 0
operational current of auxiliary contacts at AC-15  
● at 24 V 2 A
● at 110 V 2 A
● at 120 V 2 A
● at 125 V 2 A
● at 230 V 0.5 A
operational current of auxiliary contacts at DC-13  
● at 24 V 1 A
● at 60 V 0.15 A
Protective and monitoring functions
product function  
● ground fault detection No
● phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
maximum short-circuit current breaking capacity (Icu)  
● at AC at 240 V rated value 100 kA
● at AC at 400 V rated value 100 kA
● at AC at 500 V rated value 3 kA
● at AC at 690 V rated value 2 kA
operating short-circuit current breaking capacity (Ics) at AC  
● at 240 V rated value 100 kA
● at 400 V rated value 100 kA
● at 500 V rated value 3 kA
● at 690 V rated value 2 kA
response value current of instantaneous short-circuit trip unit 52 A
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor  
● at 480 V rated value 4 A
● at 600 V rated value 4 A
yielded mechanical performance [hp]  
● for single-phase AC motor  
— at 110/120 V rated value 0.13 hp
— at 230 V rated value 0.33 hp
● for 3-phase AC motor  
— at 200/208 V rated value 0.8 hp
— at 220/230 V rated value 0.75 hp
— at 460/480 V rated value 2 hp
— at 575/600 V rated value 3 hp
contact rating of auxiliary contacts according to UL C300 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link  
● for short-circuit protection of the auxiliary switch required fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit  
● at 240 V none required
● at 400 V gG 40 A
● at 500 V gG 35 A
● at 690 V gG 35 A
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height 90 mm
width 45 mm
depth 75 mm
required spacing  
● for grounded parts at 400 V  
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for live parts at 400 V  
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for grounded parts at 500 V  
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for live parts at 500 V  
— downwards 20 mm
— upwards 20 mm
— at the side 9 mm
● for grounded parts at 690 V  
— downwards 20 mm
— upwards 20 mm
— backwards 0 mm
— at the side 9 mm
— forwards 0 mm
● for live parts at 690 V  
— downwards 20 mm
— upwards 20 mm
— backwards 0 mm
— at the side 9 mm
— forwards 0 mm
Connections/ Terminals
type of electrical connection  
● for main current circuit screw-type terminals
● for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current circuit Top and bottom
type of connectable conductor cross-sections  
● for main contacts  
— solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (1 ... 4 mm²)
— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
type of connectable conductor cross-sections  
● for auxiliary contacts  
— solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
tightening torque  
● for main contacts with screw-type terminals 0.8 ... 1.2 N·m
● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv size 2
design of the thread of the connection screw  
● for main contacts M3
● of the auxiliary and control contacts M3
Safety related data
product function suitable for safety function Yes
suitability for use  
● safety-related switching on No
● safety-related switching OFF Yes
service life maximum 10 a
test wear-related service life necessary Yes
proportion of dangerous failures  
● with low demand rate according to SN 31920 40 %
● with high demand rate according to SN 31920 50 %
B10 value with high demand rate according to SN 31920 5 000
failure rate [FIT] with low demand rate according to SN 31920 50 FIT
ISO 13849
device type according to ISO 13849-1 3
overdimensioning according to ISO 13849-2 necessary Yes
IEC 61508
safety device type according to IEC 61508-2 Type A
Electrical Safety
protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front
Display
display version for switching status Rocker switch

Lebih maklumat tentang Green Energy Automation Sdn Bhd
Green Energy Automation Sdn Bhd
Green Energy Automation Sdn Bhd Industrial Process Automation & Control Systems Johor, PLC System Integration Services Malaysia | Green Energy Automation Sdn Bhd