Supply voltage |
Load voltage L+ |
● Rated value (DC) |
24 V |
● permissible range, lower limit (DC) |
20.4 V |
● permissible range, upper limit (DC) |
28.8 V |
Input current |
from load voltage L+ (without load), max. |
80 mA |
from backplane bus 5 V DC, max. |
80 mA |
Power loss |
Power loss, typ. |
6.5 W |
Digital inputs |
Number of digital inputs |
16 |
Input characteristic curve in accordance with IEC 61131, type 1 |
Yes |
Number of simultaneously controllable inputs |
horizontal installation |
— up to 40 °C, max. |
16 |
— up to 60 °C, max. |
8 |
vertical installation |
— up to 40 °C, max. |
16 |
Input voltage |
● Type of input voltage |
DC |
● Rated value (DC) |
24 V |
● for signal "0" |
-30 to +5 V |
● for signal "1" |
13 to 30V |
Input current |
● for signal "1", typ. |
7 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
— at "0" to "1", min. |
1.2 ms |
— at "0" to "1", max. |
4.8 ms |
— at "1" to "0", min. |
1.2 ms |
— at "1" to "0", max. |
4.8 ms |
Cable length |
● shielded, max. |
1 000 m |
● unshielded, max. |
600 m |
Digital outputs |
Number of digital outputs |
16 |
Short-circuit protection |
Yes |
● Response threshold, typ. |
1 A |
Limitation of inductive shutdown voltage to |
L+ (-48 V) |
Controlling a digital input |
Yes |
Switching capacity of the outputs |
● on lamp load, max. |
5 W |
Load resistance range |
● lower limit |
48 !& |
● upper limit |
4 k!& |
Output voltage |
● for signal "1", min. |
L+ (-0.8 V) |
Output current |
● for signal "1" rated value |
0.5 A |
● for signal "1" permissible range, min. |
5 mA |
● for signal "1" permissible range, max. |
0.6 A |
● for signal "1" minimum load current |
5 mA |
● for signal "0" residual current, max. |
0.5 mA |
Output delay with resistive load |
● "0" to "1", max. |
100 µs |
● "1" to "0", max. |
500 µs |
Parallel switching of two outputs |
● for uprating |
No |
● for redundant control of a load |
Yes; only outputs of the same group |
Switching frequency |
● with resistive load, max. |
100 Hz |
● with inductive load, max. |
0.5 Hz |
● on lamp load, max. |
100 Hz |
Total current of the outputs (per group) |
horizontal installation |
— up to 40 °C, max. |
4 A |
— up to 60 °C, max. |
3 A |
vertical installation |
— up to 40 °C, max. |
2 A |
Cable length |
● shielded, max. |
1 000 m |
● unshielded, max. |
600 m |
Encoder |
Connectable encoders |
● 2-wire sensor |
Yes |
— permissible quiescent current (2-wire sensor), max. |
1.5 mA |
Interrupts/diagnostics/status information |
Alarms |
No |
Diagnostics function |
No |
Diagnostics indication LED |
● Status indicator digital input (green) |
Yes |
● Status indicator digital output (green) |
Yes |
Potential separation |
Potential separation digital inputs |
● between the channels |
Yes |
● between the channels, in groups of |
16 |
● between the channels and backplane bus |
Yes; Optocoupler |
Potential separation digital outputs |
● between the channels |
Yes |
● between the channels, in groups of |
8 |
● between the channels and backplane bus |
Yes; Optocoupler |
Isolation |
Isolation tested with |
500 V DC |
connection method |
required front connector |
40-pin |
Dimensions |
Width |
40 mm |
Height |
125 mm |
Depth |
120 mm |
Weights |
Weight, approx. |
260 g |
Classifications |
|
|
Version |
Classification |
eClass |
14 |
27-24-22-04 |
eClass |
12 |
27-24-22-04 |
eClass |
9.1 |
27-24-22-04 |
eClass |
9 |
27-24-22-04 |
eClass |
8 |
27-24-22-04 |
eClass |
7.1 |
27-24-22-04 |
eClass |
6 |
27-24-22-04 |
ETIM |
10 |
EC001419 |
ETIM |
9 |
EC001419 |
ETIM |
8 |
EC001419 |
ETIM |
7 |
EC001419 |
IDEA |
4 |
3566 |
UNSPSC |
15 |
32-15-17-05 |
|
Approvals / Certificates |
General Product Approval |
Manufacturer Declaration
|

|

|
Miscellaneous
|

|

|
EMV |
For use in hazardous locations |

|

|

|

|
FM
|

|
For use in hazardous locations |
Maritime application |

|
Miscellaneous
|

|
CCC-Ex
|

|

|
Maritime application |

|
NK / Nippon Kaiji Kyokai
|

|

|
CCS (China Classification Society)
|
|
|