The OPTISOUND 3010 is a 2- or 4-wire ultrasonic level transmitter for basic applications up to 5 m / 16.4 ft. It is designed for continuous measurement of liquids such as rainwater and wastewater as well as bulk solids in nearly all sectors of industry. The level transmitter is particularly suitable for use in small tanks or in open channels for flow measurement.
Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.
Depending on selected device configuration
Product type | Level transmitter |
Product family name | OPTISOUND |
Product positioning | For basic applications up to 5 m / 16.4 ft |
Product variants | OPTISOUND 3010 C: Compact housing |
Measurement variables | Level |
Measurement principle | Ultrasonic |
Level measurement type | Continuous measurement |
Contact to measured medium | No |
Interface measurement | No |
Redundancy | No |
Measured media | Liquids, Slurries, Pastes, Solids, Bulk solids, Granulates, Powders |
Measuring range (liquids) |
0.25…5 m/ 0.82…16.4 ft |
Measuring range (solids) |
0.25…2 m/ 0.82…6.6 ft |
Measuring point | Open tank, Open basin, Open channel, Stockpile, Conveyor belt |
Process pressure |
-0.2…2 barg/ -2.9…29 psig |
Process temperature |
-40…+80°C/ -40…+176°F |
Gaskets | Ethylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM/FPM), Kalrez® 6375, PFA |
Wetted parts | Polyvinylidene fluoride (PVDF) |
Thread connections |
Male: G1 ½ 1 ½ NPT |
Certificates/Approvals Others | EAC |
Certificates/Approvals Ex | ATEX |
Certificates/Approvals Safety | SIL 2 |
Ingress protection | IP66/67, NEMA4/4X/6 |
Analogue outputs | 4…20 mA |
Digital outputs | HART® |
Accuracy (liquids) |
±4 mm/ ±0.16 in |
Accuracy (solids) |
±4 mm/ ±0.16 in |