Coating Thickness Gauge
Features:
1.Using magnetic and eddy current two thickness method can measure the thickness
of the magnetic metal matrix on the non-magnetic coating, can be measured non-
magnetic metal matrix on the thickness of the non-conductive coating;
2.Split (connection between the sensor and the lead instrument), dual (F-type N-type one);
3.The unique temperature compensation algorithm;
4.With two measurements: continuous measurement mode (CONTINUE) and a single measurement (SINGLE);
5.With statistical functions: average value (Here MEAN), maximum value (the MAX),
minimum value (the MIN), the number of tests (NO.), Standard deviation (S.DEV);
6.With storage function: can store 500 measurement values.
COATING THICKNESS GAUGE SPAREPARTS
| 
			 C-P01-001  | 
			
			 Coated Metal Plates 
  | 
			
			 Epoxy on Steel 50x60mm  | 
			
			 
  | 
		
| 
			 C-P01-0002  | 
			
			 Coated Metal Plates 
  | 
			
			 Epoxy on Aluminum 50x60mm  | 
			
			 
  | 
		
| 
			 
  | 
			
			 Plastic shims 
  | 
			
			 50,100,250,500,1000 5pcs as one set  | 
			
			 --  | 
		
| 
			 C-P02-0001  | 
			
			 10um  | 
			
			 Accuracy±0.3%  | 
		|
| 
			 C-P02-0002  | 
			
			 20um  | 
			
			 Accuracy±0.3%  | 
		|
| 
			 C-P02-0003  | 
			
			 50um  | 
			
			 Accuracy±0.3%  | 
		|
| 
			 C-P02-0004  | 
			
			 100um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0005  | 
			
			 250um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0006  | 
			
			 500um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0007  | 
			
			 1000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0008  | 
			
			 2000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0009  | 
			
			 3000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0010  | 
			
			 4000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0011  | 
			
			 5000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0012  | 
			
			 6000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0013  | 
			
			 7000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0014  | 
			
			 8000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P02-0015  | 
			
			 10000um  | 
			
			 Accuracy±0.6%  | 
		|
| 
			 C-P03-005  | 
			
			 Ceramic calibration block 
  | 
			
			 500um  | 
			
			 --  | 
		
| 
			 C-P03-006  | 
			
			 600um  | 
			
			 --  | 
		|
| 
			 C-P03-007  | 
			
			 700um  | 
			
			 --  | 
		|
| 
			 C-P03-008  | 
			
			 800um  | 
			
			 --  | 
		|
| 
			 C-P03-009  | 
			
			 900um  | 
			
			 --  | 
		|
| 
			 C-P03-0010  | 
			
			 1000um  | 
			
			 --  | 
		|
| 
			 C-P03-0015  | 
			
			 1500um  | 
			
			 --  | 
		|
| 
			 C-P03-0020  | 
			
			 2000um  | 
			
			 --  | 
		|
| 
			 C-P03-0025  | 
			
			 2500um  | 
			
			 --  | 
		|
| 
			 C-P03-0030  | 
			
			 3000um  | 
			
			 --  | 
		|
| 
			 C-P03-0040  | 
			
			 4000um  | 
			
			 --  | 
		|
| 
			 C-P03-0080  | 
			
			 8000um  | 
			
			 --  | 
		
Coating Thickness Probe
Technical parameters
   F-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
    N-type probe use of eddy current way, measurable magnetic non-ferrous metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive, Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics, anodizing film ).
    F / N-probe (except N400) gage with the times and can be used, other brands gage would need change.
F1 probe

 F1-use magnetic probe, based on measurable magnetic metal (such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Measuring range :0-1250 um
Measurement accuracy: one point calibration: ± (3% H +1), two point calibration: ±
(1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 1.5
The smallest diameter: f7
Matrix critical thickness: 0.5
F10 probe:
 
F10-use magnetic probe, based on measurable magnetic metal (such as steel, iron,
steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Range: 0 - 10mm
Measurement accuracy: one point calibration: ± (3% H +10) ;two point calibration: ±
(1% H +10)
Low-limit resolution: 1
Minimum radius of curvature (convex): 10
The smallest diameter: f40
Matrix critical thickness: 2
F1/90 probe

F1/90 of the probe using magnetic method, based on measurable magnetic metal
(such as steel, iron, steel alloys and hard-magnetic, etc.) on non-magnetic coating
thickness (such as zinc, aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Measuring range :0-1250 um
Measurement accuracy: one point calibration: ± (3% H +1);two point calibration: ±
(1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): straight
The smallest diameter: f7
Matrix critical thickness: 0.5
 
F400 probe
 
F400-use magnetic probe, based on measurable magnetic metal (such as steel, iron,
steel alloys and hard-magnetic, etc.) on non-magnetic coating thickness (such as zinc,
aluminum, chromium, copper, rubber, paint, etc.).
Measuring principle: magnetic
Measuring range :0-400 um
Measurement accuracy: one point calibration: ± (3% H +0.7) two point calibration: ±
(1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 1
The smallest diameter: f3
Matrix critical thickness: 0.2
N1 probe
 
N1 type eddy current probe the eddy current way, measurable magnetic non-ferrous
metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive,
Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics,
anodizing film )
Measuring principle: Eddy
Measuring range :0-1250 um
Measurement accuracy (um): one point calibration ± (3% H +1.5) ;two point
calibration: ± (1% H +1.5)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 3
The smallest diameter: f5
Matrix critical thickness: 0.3
N400 probe
 
N400-eddy current probe by the eddy current way, measurable magnetic non-ferrous
metal matrix (such as copper, aluminum, zinc, tin, etc.) and non-conductive,
Austenitic stainless steel cover the thickness (such as: rubber, paints, plastics,
anodizing film )
Measuring principle: Eddy
Measuring range :0-400 um
Measurement accuracy (um): one point calibration: ± (3% H +1)
two t point calibration: ± (1% H +1)
Low-limit resolution: 0.1
Minimum radius of curvature (convex): 1.5
The smallest diameter: f4
Matrix critical thickness: 0.3