Thrust force and Torque are measured simultaneously.
Rated Output is adjusted at ±5 V
in both Mz and Fz direction.
Just connect a sensor and apply 24 V to it, then adjusted voltage will be outputted simultaneously.
Any calibration settings are not required.

 
| Model | Sensor : URT-20-5K Amplifier : FS200 | 
|---|---|
| Rated capacity | Mz : ±20 Nm Fz : 5 kN | 
| Power supply voltage | DC 24 V±15% | 
| Consumption current | 150 mA or less | 
| Load signal output | Mz, Fz : ±5 V | 
| Load resistance | 2 k!& or more | 
| Response | 2 kHz | 
| I/O signal | Input: Auto zero command Output: Auto zero response  | 
		
| Safe overload | Mz:500% FS Fz:400% FS | 
| Non-linearity | Mz:0.1% FS typ., Fz:0.5% FS or less | 
| Hysteresis | Mz:0.1% FS typ., Fz:0.5% FS or less | 
| Repeatability | Mz:0.1% FS typ., Fz:0.5% FS or less | 
| Cross talk | Mz(20 Nm) → Fz:0.05 kN or less Fz(5 kN) → Mz:0.2 Nm or less  | 
		
| Compensated temp. range | 0 to +40℃ | 
| Safe temp. range | -10 to +50℃ | 
| Temp. effect on zero | 0.1% FS/℃ or below | 
| Temp. effect on span | 0.05% FS/℃ or below | 
| Sensor material | Stainless steel | 
| Weight | Sensor:Approx. 250 g, Amplifier:Approx. 180 g  | 
		
*Above specifications are achieved when the sensor(URT-20-5K) is connected with the dedicated amplifier(FS200).
*Accuracy is not guaranteed in the range of Fz 0 to -5 V.
 

 
Please note that there are possibilities of individual differences in a color tone on display devices such as LEDs, fluorescent display tubes and LCDs due to manufacturing process or production lots.
Malaysia