| 2512 | - | □ | - | □ | - | □ |
| ① | ② | ③ |
| Model | Measuring Range | Input Resistance | Over Load |
|---|---|---|---|
| 02 | ± 99.99 mV | 10 kΩ | DC ±10 V |
| 03 | ± 999.9 mV | 100 kΩ | DC ±100 V |
| 04 | 0 to 5 V | 500 kΩ | DC ±250 V |
| 05 | ± 9.999 V | 1 MΩ | DC ±250 V |
| 06 | ± 99.99 V | 1 MΩ | DC ±250 V |
| 09 | 1 to 5 V | 1 MΩ | DC ±250 V |
| 00 | DC voltage input other than the above. (In between 100 mV and 100 V) | ||
| 22 | ± 99.99 μA | 1 kΩ | DC ±20 mA |
| 23 | ± 999.9 μA | 100 Ω | DC ±50 mA |
| 24 | ± 5.000 mA | 20 Ω | DC ±100 mA |
| 25 | ± 9.999 mA | 10 Ω | DC ±150 mA |
| 26 | ± 9.999 mA | 1 Ω | DC ±500 mA |
| 27 | ± 9.999 mA | 0.1 Ω | DC ±2 A |
| 29 | 4 to 20 mA | 12.5 Ω | DC ±150 mA |
| 20 | DC current input other than the above. (In between 100 μA and 100 mA) | ||
| 25 | □ | 2 | - | □ | - | □ |
| ① | ② | ③ |
| Code | Temperature Sensor | Measuring Range | Display Range |
|---|---|---|---|
| 2 | R | 100 to 1768°C | -50 to 1800°C |
| K | -200 to 1372°C | -270 to1400°C | |
| E | -200 to 1000°C | -270 to 1050°C | |
| J | -200 to 1200°C | -210 to 1250°C | |
| T | -200 to 400°C | -270 to 420°C | |
| B | 600 to 1800°C | -20 to 1820°C | |
| N | -200 to 1300°C | -230 to 1350°C | |
| S | 0 to 1768°C | -50 to 1800°C | |
| WRe5-26 | 0 to 2320°C | -20 to 2350°C |
| Code | Temperature Sensor | Measuring Range | Display Range |
|---|---|---|---|
| 3 | Pt100Ω (JIS’97) | -200 to 850°C | -200 to 870°C |
| JPt100Ω (JIS’81) | -200 to 649°C | -200 to 660°C | |
| Pt50Ω (JIS’81) | -200 to 649°C | -200 to 660°C | |
| Ni508.4Ω | -200 to 280°C | -50 to 300°C |
| Specification / Model | 2512 | 2522 | 2532 | ||
|---|---|---|---|---|---|
![]() |
![]() |
![]() |
|||
| Dimension (W x H x D mm) excl .Base socket | 28.5 × 72 × 115 | ||||
| Input | DC current / voltage | ● | - | - | |
| Process | ● | - | - | ||
| T/C (R,K,E,J,T,B,N,S,WRe5-26) | - | ● | - | ||
| RTD (Pt100Ω,JPt100Ω,Pt50Ω,Ni508.4Ω) | - | - | ● | ||
| Output | Nos. of Alarm | 2points | ● | ● | ● |
| 4points | ● | ● | ● | ||
| Accuracy | Repeatability | ±(0.1% of FS + 1digit) | |||
| Output | Relay | ● | ● | ● | |
| Open collector | ● | ● | ● | ||
| Setting style | Key | ● | ● | ● | |
| Alarm type (H/L) | H or L adjustable | ● | ● | ● | |
| Comparator ON/OFF Switchable | ● | ● | ● | ||
| Rating | Relay | 250 V, 1 A a.c., 30 V, 2 A d.c. | |||
| Open collector | 50 V, 100 mA d.c. | ||||
| Response | Less than 150ms | Less than 400ms | Less than 1.2s | ||
| Display | 4 digit ( -9999 to 9999) | ● | ● | ● | |
| Zero suppress | ● | ● | ● | ||
| Scaling | ● | - | - | ||
| Off display | ● | ● | ● | ||
| Offset | ● | - | - | ||
| Status | ● | ● | ● | ||
| Function | Hysteresis | ● | ● | ● | |
| Output delay | ● | ● | ● | ||
| Power on delay | ● | ● | ● | ||
| Deviation setting | ● | ● | ● | ||
| Test mode | ● | ● | ● | ||
| Moving average | ● | ● | ● | ||
| Operating temperature | 0-50°C | ||||
| Operating humidity | 30 - 90% RH (no condensation) | ||||
| AC power supply | 100 to 240 V a.c. | ||||
| DC power supply | 12 to 24 V d.c., 110 V d.c. | ||||
| Weight | approx. 180 g | ||||
●:Standard, ○:Option