The MicroFlow-i delivers accurate, repeatable velocity measurement for liquid flow, either as an individual sensor or by providing HART communication protocol or a 4-20mA loop-powered signal into an accompanying data logging system.
_____________________________________________________________________________________________________________________________________________________________
TECHNICAL SPECIFICATIONS:
| General Specifications | |
|---|---|
| Spec name: | Description: |
| Sensor Body Dimensions: | 90 mm x 140 mm (3.54 in x 5.51 in) |
| Weight: | 1 kg (2.2 lbs) |
| Sensor Body Material: | Valox 357 |
| Maximum Separation: | Up to 1,000 m (3,280 ft) |
| Max. and Min Temperature (Electronics): | -20 °C to +60 °C (-4 °F to +140 °F) |
| Velocity Range: | 0.2 m/s to 6 m/s (0.66 ft/s to 19.7 ft/s) |
| Optimum Installation: | Install and an angle of 45° in line with the flow. More information is available in the manual. |
| Outputs: | HART and 4-20mA loop powered |