In the 2026 Malaysian regulatory landscape, BOMBA Certified HVAC refers to Air Conditioning and Mechanical Ventilation (ACMV) systems that satisfy the life-safety mandates of the Fire Services Act 1988 (Act 341) and the Uniform Building By-Laws (UBBL) 2026.
As of February 3, 2026, new regulations specify that all HVAC installations must meet rigorous fire-safety standards to obtain or renew a Fire Certificate (FC).
The AHU Safety Permit is a mandatory prerequisite for BOMBA clearance. Under the 2026 framework, HVAC systems are primary components of the building’s Active Fire Protection.
Smoke Control Integration: For units serving areas larger than 92.9 square metres (1,000 sq. ft.), BOMBA mandates a Duct Smoke Detector linked to the Fire Alarm Monitoring System (FAMS).
Automatic Shut-off Protocol: Upon smoke detection, the system must trigger an immediate power-cut to the IE5 EC Fan Walls to prevent the HVAC from acting as a "smoke pump" that recirculates toxic fumes.
BOMBA "K" Mark Compliance: All active fire components—including motorized dampers and sensors—must carry a valid BOMBA "K" Mark or be registered in the eFEIS 2.0 system.
A BOMBA-certified setup requires specific hardware to maintain the fire-rating of the building's compartments.
| Component | BOMBA 2026 Requirement | Engineering Purpose |
| Motorized Fire Dampers | MS 558 Certified / UL-Listed | Automatically seals duct penetrations in under 20 seconds. |
| Duct Smoke Detectors | Photoelectric / Interlocked | Triggers localized shutdown before smoke enters the air stream. |
| Fire-Rated (FR) Cabling | MS 2116 Compliant (Class C) | Ensures the shut-off signal survives the high heat of a fire. |
| Casing Insulation | Non-Combustible (Class 0) | Prevents the AHU from contributing to the plant room fire load. |
To secure certification, the installation must pass a physical witness test by a BOMBA officer:
Smoke Injection Test: Non-toxic smoke is injected into the return air plenum to verify the Automatic Fire Signal AHU Shut-off response time.
Fire Damper Integrity: Verification that all dampers close fully and that the "Damper-to-Wall" interface is sealed with BOMBA-approved intumescent fire-stop mortar.
Fireman’s Switch Verification: Validation of the manual override switch located in the Fire Control Room, allowing emergency responders to control the fan systems manually.
A critical challenge in 2026 is ensuring fire-safety components do not compromise energy efficiency.
Low-Pressure Drop Dampers: We utilize aerofoil-blade dampers that meet fire ratings while maintaining the low resistance needed to satisfy your Specific Fan Power (SFP) targets.
Acoustic & Safety Balance: Our setups maintain the NC 30-35 "Silent Office" standard while ensuring that seismic restraints and fire-safing are fully integrated.
Technical Integrity: Our installations are overseen by mechanical engineers who understand the complex relationship between HVAC thermodynamics and Active Fire Protection.
Submission Management: We manage the entire BOMBA Form B and G8/G9 documentation process to ensure your permit is issued without delays.
GITA Support: Documented BOMBA compliance is essential for claiming the 100% Green Investment Tax Allowance on high-performance HVAC equipment.
Is your HVAC installation safe enough to pass a 2026 BOMBA audit? Contact EKG (Malaysia) SDN BHD today for a specialized BOMBA Certified HVAC Assessment.
Are you applying for a safety permit for a new high-rise project or as part of a fire safety upgrade for an existing facility?
更多 EKG M & E SDN BHD 相关资料
Malaysia