BOMBA Certified Air Handling Unit Setup

BOMBA Certified Air Handling Unit Setup

分类: BOMBA Certified AHU Installation 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

BOMBA Certified AHU Setup: Statutory Standards 2026

In the 2026 Malaysian regulatory landscape, a BOMBA Certified AHU Setup is no longer a recommendation—it is a mandatory legal requirement under the Fire Services Act 1988 (Act 341) and the Uniform Building By-Laws (UBBL) 2026. As of February 3, 2026, new regulations specify that all air-handling equipment must meet strict fire-safety standards to obtain or renew a Fire Certificate (FC).

 

At EKG (Malaysia) SDN BHD, we specialize in the engineering of BOMBA-certified configurations that ensure your assets are Sterile, Silent, and Statutory-Compliant.


1. The Statutory Requirement: AHU Safety Permit

The AHU Safety Permit is the core document required for BOMBA clearance. Without this, your building’s Certificate of Completion and Compliance (CCC) can be withheld.

  • Smoke Control Integration: For units serving areas over 92.9 sq. meters (1,000 sq. ft.), BOMBA mandates integration with the Fire Alarm Monitoring System (FAMS).

  • Automatic Shutdown Protocol: The setup must feature a "kill-signal" interlock. Upon fire detection, the IE5 EC Fan Walls must shut down in milliseconds to prevent the AHU from acting as a smoke pump.

  • BOMBA "K" Mark Compliance: All active fire components, such as motorized dampers and smoke detectors, must carry the valid BOMBA "K" Mark or be registered in the eFEIS 2.0 system.


2. Technical Blueprint of a Certified Setup

A certified setup is designed as a "Fire-Safe Cell" that preserves the integrity of fire compartments.

Component 2026 BOMBA Requirement Engineering Purpose
Motorized Fire Dampers MS 558 Certified / UL-Listed Automatically seals duct penetrations in under 20 seconds.
Duct Smoke Detectors Photoelectric / Interlocked Triggers localized AHU shutdown before smoke recirculates.
Fire-Rated (FR) Cabling MS 2116 Compliant Ensures the shut-off signal survives the high heat of a fire.
Casing Insulation Non-Combustible (Class 0) Prevents the unit from contributing to the plant room fire load.

3. Site Inspection & Functional Testing (BOMBA Audit)

To secure the permit, the installation must pass a physical witness test by a BOMBA officer:

  1. Smoke Injection Test: We inject non-toxic smoke into the return air plenum to verify the Automatic Fire Signal AHU Shut-off response.

  2. Fire Damper Audit: Verification that all dampers close fully and that the "Damper-to-Wall" interface is sealed with BOMBA-approved intumescent fire-stop mortar.

  3. Fireman's Switch Verification: Validation of the manual override switch located in the Fire Control Room.


4. Integration with EECA 2024

A unique challenge in 2026 is ensuring that BOMBA safety components do not compromise energy efficiency.

  • Low-Pressure Drop Dampers: We utilize aerofoil-blade dampers that meet fire ratings while maintaining the low resistance needed to satisfy your Specific Fan Power (SFP) targets.

  • Acoustic & Safety Balance: Our setups maintain the NC 30-35 "Silent Office" standard while ensuring seismic restraints and fire-safing are fully integrated.


5. Why Partner with EKG (Malaysia) SDN BHD?

  • Technical Integrity: We are mechanical engineers who understand the complex intersection of HVAC thermodynamics and Active Fire Protection.

  • Submission Management: We handle the entire BOMBA Form B and G8/G9 documentation process to ensure your permit is issued without delays.

  • GITA Support: Documented BOMBA compliance is essential proof for claiming the 100% Green Investment Tax Allowance.

Is your AHU setup safe enough to pass a 2026 BOMBA audit? Contact EKG (Malaysia) SDN BHD today for a specialized BOMBA Certified Setup & Audit.

Are you applying for a permit for a new high-rise project or retrofitting an existing industrial facility?

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD