详情
        FLIR A400/A700 Professional Science Kit
FLIR A400 and A700 Science Kits offer researchers and engineers a streamlined solution for accurate temperature measurement. Simplified yet robust connections help you set up and start testing quickly; then easily view, acquire, and analyze data using included FLIR Research Studio software. The Standard kit includes a FLIR A400 or A700 Image Streaming camera, 24° lens with automatic/remote and manual focusing, as well as FLIR Macro Mode. The Professional kit has the added benefits of MSX® image enhancement, radiometric data transmission over Wi-Fi, and a close-up lens for accurate thermal measurements on small components.
SPECIFICATIONS
	- IR Resolution
 
	- 320 × 240
 
	- Detector Pitch
 
	- 17 µm
 
	- Pixel Pitch
 
	- 17 µm
 
	- Spectral Range
 
	- 7.5–14.0 µm
 
	- Detector Type
 
	- Uncooled microbolometer
 
	- Dynamic Range
 
	- 16-bit
 
	- Thermal Sensitivity/NETD
 
	- Lens dependent: <30 mK to <50 mK
 
	- Frame Rate
 
	- 30 Hz
 
	- Standard Temperature Range
 
	- -20°C to 120°C (-4°F to 248°F); 0°C to 650°C (32°F to 1202°F); 300°C to 1500°C (572°F to 2732°F)
 
	- Focus
 
	- One-shot contrast, motorized, manual
 
 
	- Available Lenses
 
	- 6°, 14°, 42°
 
	- Detector Pitch
 
	- 17 µm
 
	- Detector Type
 
	- Uncooled microbolometer
 
	- Digital Data Streaming to PC
 
	- Gigabit Ethernet (RTSP, GigE Vision) or Wi-Fi stream to workstation running included Research Studio Software
 
	- Dynamic Range
 
	- 16-bit
 
	- Field of view (FOV)
 
	- 24° × 18°
 
	- Focus
 
	- One-shot contrast, motorized, manual
 
	- Frame Rate
 
	- 30 Hz
 
	- Image Modes
 
	- MSX®, Picture-in-picture, blending, and fusion
 
	- IR Resolution
 
	- 320 × 240
 
	- Lens
 
	- 24°, 2.0x Macro
 
	- Lens Identification
 
	- Automatic
 
	- Macro Mode
 
	- Included
 
	- Minimum Focus Distance
 
	- 2.0x Macro: 18 mm (0.71 in) 24°: 0.15 m (0.49 ft) 24° with Macro Mode: 17 mm (0.67 in) 42°: 0.15 m (0.49 ft) 14°: 1.0 m (3.28 ft) 6°: 5.0 m (16.4 ft)
 
	- Pixel Pitch
 
	- 17 µm
 
	- Spectral Range
 
	- 7.5–14.0 µm
 
	- Thermal Sensitivity/NETD
 
	- Lens dependent: <30 mK to <50 mK
 
	- Visible Camera
 
	- 1280x960
 
 
	- Accuracy
 
	- ±2°C (±3.6°F) or ±2% of reading for ambient temperature 15°C to 35°C (59°F to 95°F), object temperature above 0°C (32°F)
 
	- Standard Temperature Range
 
	- -20°C to 120°C (-4°F to 248°F); 0°C to 650°C (32°F to 1202°F); 300°C to 1500°C (572°F to 2732°F)
 
 
	- Command and Control
 
	- Gigabit Ethernet (RTSP, GigE Vision), Wi-Fi
 
	- Digital I/O connector type
 
	- M12 Male 12-pin A-coded (shared with ext. power)
 
	- Digital Inputs
 
	- 2× opto-isolated, Vin (low) = 0–1.5 V, Vin (high) = 3–25V
 
	- Digital Outputs
 
	- 3× opto-isolated, 0–48 VDC, max. 350 mA (derated to 200 mA at 60°C). Solid-state opto relay, 1× dedicated as fault output (NC)
 
	- Ethernet Communication
 
	- GigE Vision ver. 1.2, Client API GenICam compliant, TCP/IP socket-based (FLIR proprietary)
 
	- Ethernet Connector Type
 
	- M12 8-pin X-coded, female
 
	- Ethernet Image Streaming
 
	- Yes
 
	- Ethernet Power
 
	- Power over Ethernet, PoE IEEE 802.3af class 3
 
	- WiFi
 
	- Connector: Female RP-SMA Standard: IEEE802.11a/b/g/n Connections: Peer to peer (ad hoc) or infrastructure (network)
 
 
	- Size [L x W x H ] w Lens
 
	- 123 × 77 × 77 mm (4.84 × 3.03 × 3.03 in)
 
 
	- External Voltage
 
	- 18-56 VDC, 8 W max
 
	- Power
 
	- 24/48 V DC 8 W max
 
	- Power Cable Configuration
 
	- Power over Ethernet or External
 
	- Power Connection
 
	- M12 Male 12-pin A-coded (shared with Digital I/O)
 
 
	- Encapsulation
 
	- IEC 60529, IP 54, IP66 with accessory
 
	- Mounting
 
	- UNC ¼″-20 on 2 sides 4× M4 on 4 sides
 
	- Operating Temperature
 
	- -20°C to 50°C (-4°F to 122°F): • -20°C to 40°C (-4°f to 104°F) (in free air) • 40°C to 50°C (104°F to 122°F) (mounted on cooling plate accessory) • Maximum camera case temperature: 65°C (149°F)
 
	- Shock
 
	- IEC 60068-2-27, 25 g
 
	- Storage Temperature Range
 
	- IEC 68-2-1 and IEC 68-2-2, -40°C to 70°C (-40°F to 158°F) for 16 hours
 
	- Vibration
 
	- IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal IEC 61373 Cat 1 (Railway)
 
 
 
        更多 Accutac Sdn Bhd 相关资料