LCS Ocea!" Spiral (Multifocal Lenses)

LCS Ocea!" Spiral (Multifocal Lenses)

Category: 3-Monthly Disposables Available
For more information, visit our official website at intanoptometry.com.my

Specifications
  • Packing: 1/pk
  • Material: Silicone Hydrogel
  • Power Range: - 11.00 to +11.00 D ( 0.25 D) Cyl: up to -0.75 All axes (in 1° step) Addition: Low: If spectacle addition between 0.75 and 1.00 Med: If spectacle addition between 1.25 and 1.75 High: If spectacle addition between 2.00 and 2.50
  • Diameter (mm): 14.40 mm
  • Base Curve (mm): 8.40 mm
Description

Ocea Spiral Range

Advanced Wavefront Control Custom Silicone Hydrogel Lenses Utilizing Micro-Optic Optical Vortex Technology to Neutralize Higher-Order Aberrations

Core Concept Technology

Optical Vortex Rotation

Geometric Design Base

Micro-Optic Front Surface

Material Substrate

SiH65 Silicone Hydrogel

Replacement Cycle

Quarterly (3 Months Wear)

Design Adaptations & Functional Mapping

Ocea Spiral HD

Myopes & Hyperopes

Engineered explicitly for patients experiencing clear distance vision issues due to structural corneal micro-irregularities or higher-order visual aberrations. This lens creates stability across all focal lines without regular geometric toric constraints.

  • Higher-Order Correction: Neutralizes asymmetric structural ocular wavefront gaps via localized micro-toric front surface rotations.
  • Built-In Astigmatism Buffer: Comfortably compensates for natural direct corneal astigmatism up to -0.75 D out of the box without requiring specialized prism structures.
  • Optimized Transmissibility: Combines the visual sharpness parameters of premium customized geometry with the high oxygen breathability of a flexible custom lens matrix.

Ocea Spiral Low / Med / High

Presbyopes

Designed as a targeted correction profile for presbyopic wearers who require natural intermediate transitions and crisp reading alignment without compromising overall baseline distance stability.

  • Micro-Optic Vortex: Generates continuous visual transitions (VL/VP) by structuring light travel into concentric power rings.
  • Presbyopic Power Step Categories: Stratified into clear 3-tiered standardized range divisions (Low, Medium, High) matched to objective reading depth additions.
  • Advanced Surface Option: Supports full customization upgrades with Hydra-PEG premium surface modification to ensure prolonged tear-film retention.

Manufacturing & Structural Parameters

Technical Axis Dimension Operational Specification Profile
Lens Substrate Matrix SiH65 Silicone Hydrogel (Premium high Dk configuration)
Total Built Diameter (ØT) Standardized at 14.40 mm
Base Curve Profile (BC) Standardized at 8.40 mm
Spherical Power Scope (P) -11.00 D to +11.00 D (manufactured in precise 0.25 D steps)
Astigmatism Compensation Limit Corrects standard baseline direct astigmatism up to 0.75 D natively
Surface Treatment Options Hydra-PEG premium treatment coating matrix available on order demand
Recommended Solution Care Multipurpose soft lens maintenance solution, or hydrogen peroxide-based neutralization systems (+ weekly protein removal steps)
Clinical Removal Protocol Standard manual soft lens digital extraction ("pinching" technique)

First Intention Fitting Protocols

Ocea Spiral HD (Baseline Blueprint)

For patients requiring primary myopia or hyperopia correction alongside advanced aberration minimization:

Diameter Command: ØT = 14.40 mm

Base Curve Curve: BC = 8.40 mm

Power Optimization Rule: P = Vertex-corrected sphere value

 CLINICAL NOTE: Do not utilize or order using a spherical equivalent calculation pattern.

Ocea Spiral Low / Med / High Selection

Utilize the precise 14.40 / 8.40 structural chassis parameters above, and select the specific addition category directly derived from the patient's objective spectacle refraction prescription matrix:

Addition Tier Matrix Guide:
  • Low Design: Apply if the objective spectacle reading addition measures between +0.75 D and +1.00 D
  • Med Design: Apply if the objective spectacle reading addition measures between +1.25 D and +1.75 D
  • High Design: Apply if the objective spectacle reading addition measures between +2.00 D and +2.50 D

More detail about Intan Optometry Clinic
Intan Optometry Clinic
Intan Optometry Clinic Optometrist Petaling Jaya (PJ) | Ortho K Lens Fitting KL | Affordable Multifocal Glasses Selangor - Intan Optometry Clinic
Contact Us flagMalaysia