Fire-Rated (BS 476) Flexible Ducting

Fire-Rated (BS 476) Flexible Ducting

Category: Flexible Ducting for Terminal Connections Available
For more information, visit our official website at eakon.com.my

Description

Fire-Rated (BS 476) Flexible Ducting by EKG (Malaysia) Sdn Bhd

In 2026, Fire-Rated Flexible Ducting is a non-negotiable life-safety component for any commercial or industrial HVAC installation. Under the Uniform Building By-Laws (UBBL) 2026 and the Fire and Rescue Department (BOMBA) Malaysia standards, terminal connections within ceiling voids must be constructed from materials that inhibit flame spread and minimize smoke toxicity. For developments in Kuala Lumpur and Selangor, maintaining a 5-Star BEI requires fire-rated systems that do not compromise on hermetic integrity or airflow efficiency.

At EKG (Malaysia) Sdn Bhd, we apply 34 years of mechanical engineering expertise to provide instrument-verified, fire-rated flexible ducting. We ensure your terminal connections are safe, compliant with MS 1525, and optimized for a 5-Star Building Energy Index (BEI).


1. The Engineering Logic: The "Fire-Safe" Transition

Fire-rated flexible ducts are engineered to act as a barrier against the "Chimney Effect," where fire or smoke can travel rapidly through a building's ventilation paths.


2. Specialized Fire-Rated Integration Protocols

To meet SIRIM and BOMBA 2026 benchmarks, EKG utilizes a rigorous "Safety-First" handshake:

A. Multi-Layer Fire-Retardant Laminate

Our ducts feature a reinforced aluminum and polyester laminate core, specially treated with flame-retardant additives. This is encased in R-6.0 High-Density Non-Combustible Insulation (such as rockwool or glasswool) and protected by a fire-rated outer jacket. This construction ensures the duct remains structurally sound even when exposed to direct heat.

B. Hermetic Seal & Fire-Damper Handshake

The connection between the flexible duct and the rigid branch must be as strong as the duct itself. We utilize Stainless Steel Band Clamps and BOMBA-certified fire-rated mastic to ensure a SMACNA Class C airtight seal. Where the duct passes through a fire-rated wall, we integrate it with BOMBA-approved fire dampers for absolute compartmentalization.

C. Smart Length & Support Management

To ensure the fire-rated jacket performs as intended, the duct must be correctly supported. We strictly adhere to a maximum 2.5-meter length and utilize fire-resistant support cradles. This prevents the duct from drooping onto hot surfaces or electrical components, securing your 5-star safety rating.


3. Compliance Matrix: Standard Flex vs. EKG Fire-Rated System

Performance Metric Standard Flexible Duct EKG Fire-Rated (BS 476) Flex
Flame Spread Class 1 or 2 Class 0 (BS 476 Part 7)
Heat Release Unregulated Low Propagation (BS 476 Part 6)
Smoke Profile Potentially Toxic Low-Smoke Zero-Halogen (LSZH)
Leakage Class Class B SMACNA Class C (Hermetic)
EECA 2024 Status Regulatory Risk Audit-Ready / 5-Star BEI Support

4. Why 5-Star Fire-Rated Flex is Essential for 2026

Why Choose EKG (Malaysia) Sdn Bhd?

Is your terminal air delivery a hidden fire risk and energy waste, or is it a model of 5-star engineered safety? Contact EKG (Malaysia) Sdn Bhd today for specialized fire-rated flexible ducting solutions.

More detail about EKG M & E SDN BHD
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD