Intelligent, adaptive cooling with maximum energy savings.
VFD Controlled Cooling Water Pumps use Variable Frequency Drives to precisely match pump speed—and therefore flow and pressure—to the real-time cooling demand of the system. EKG Malaysia designs, installs, and optimizes these systems for chiller condensers, cooling towers, and process cooling loops, typically reducing pump energy consumption by 30–60% while improving control and reliability.
How It Works & Key Benefits:
Demand-Based Speed Control: The VFD adjusts the motor's electrical frequency, slowing the pump down when full cooling capacity isn't needed (e.g., at night, in cooler weather, or during low process loads).
Major Energy Savings: Pump power consumption is proportional to the cube of the speed. A 20% speed reduction yields nearly 50% power savings.
Precise Temperature/Pressure Control: Maintains optimal condenser approach temperature or cooling tower basin level by responding to sensor feedback.
Soft Start & System Protection: Eliminates high inrush current and reduces mechanical stress on pumps, pipes, and valves.
Reduced Maintenance: Lower operating speeds decrease wear on seals, bearings, and impellers.
Typical Cooling System Applications:
Chiller Condenser Water Pumps: VFD adjusts flow based on condenser water temperature or chiller load.
Cooling Tower Circulation Pumps: Speed controlled by tower basin level or leaving water temperature.
Process Cooling Loops: Maintains precise supply temperature to heat exchangers or equipment.
Variable Primary Flow (VPF) Chilled Water Systems: Controls flow to match building cooling demand while protecting chillers.
Our VFD Integration & Optimization Service:
Feasibility & Energy Audit: Logging existing pump operation to quantify potential savings and ROI.
System Design:
Selecting the correct VFD and bypass circuit.
Determining the optimal control strategy and sensor placement.
Professional Installation & Wiring: Safe electrical work, proper grounding, and harmonic mitigation if required.
Programming & Commissioning:
Configuring PID control loops for stable operation.
Setting minimum/maximum speed limits for pump protection.
Integrating with BMS (BACnet, Modbus).
Performance Verification & Tuning: Measuring post-installation energy use and fine-tuning for peak efficiency.
Why VFD Control is Ideal for Malaysia's Climate:
Cooling systems rarely operate at peak design load. A VFD captures the massive savings available during the extended part-load conditions typical of tropical operations.
Transform your largest cooling energy user into a smart asset.
The payback period for a VFD retrofit on a cooling water pump is often less than 2 years.
Contact EKG Malaysia to discuss VFD control for your cooling water pumps. We engineer solutions that deliver measurable efficiency gains and superior control.