Parameter Symbol Min Typical Max Unit Condition
Forward Voltage VF - 1.2 1.5 V IT = 1 A, Tj = 25°C
Holding Current IH 5 - 15 mA VT = 10 V, Tj = 25°C
Latching Current IL 10 - 30 mA VT = 10 V, Tj = 25°C
Peak Forward Surge Current IFSM - - 100 A t = 10 ms, Tj = 25°C
Maximum Repetitive Peak Forward Voltage VDRM - - 600 V Tj = 25°C
Maximum Repetitive Peak Reverse Voltage VRRM - - 600 V Tj = 25°C
Maximum RMS On-State Current IT(RMS) - - 16 A Tj = 25°C, sinewave
Gate Trigger Current IGT 5 - 15 mA VGT = 4 V, IT = 1 A, Tj = 25°C
Gate Trigger Voltage VGT - 1.5 2.5 V IGT = 10 mA, IT = 1 A, Tj = 25°C
Junction Temperature Tj - - 125 °C -
Storage Temperature Tstg -40 - 125 °C -

Instructions for Use:

  1. Handling Precautions:

    • Handle the BT137B-600E with care to avoid damage.
    • Avoid exposing the device to excessive mechanical stress or thermal shock.
  2. Mounting:

    • Ensure proper heat sinking if operating at high currents or in high ambient temperatures.
    • Use recommended PCB layout guidelines to minimize parasitic inductance and capacitance.
  3. Electrical Connections:

    • Connect the gate (G) to the control circuit with a short, low-inductance wire.
    • Ensure that the main terminals (MT1 and MT2) are connected correctly to avoid reverse polarity.
  4. Thermal Management:

    • Monitor the junction temperature (Tj) to ensure it does not exceed 125°C.
    • Use appropriate cooling methods such as heatsinks or forced air cooling if necessary.
  5. Gate Drive:

    • Apply a gate trigger current (IGT) within the specified range to ensure reliable turn-on.
    • The gate trigger voltage (VGT) should be within the specified limits to avoid overvoltage.
  6. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage from excessive currents.
    • Use fuses or current limiters in the circuit design.
  7. Storage:

    • Store the device in a dry, cool place away from direct sunlight and corrosive environments.
    • Observe the storage temperature range (-40°C to 125°C).
  8. Testing:

    • Perform initial testing at room temperature and gradually increase the load to verify performance.
    • Regularly inspect the device for signs of wear or damage during operation.
  9. Compliance:

    • Ensure that the device is used in compliance with all relevant safety and regulatory standards.