High-performance multiparameter water quality meter contains 8 measurement modes, suitable for measuring pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen.
pH Mode:
• Portable multiparameter water quality meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration Mode:
• 2 to 5 points calibration, including the selection of 8 concentration points.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement errors.
Other Features:• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Auto-power off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,   date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to a PC.
• Multi-mode power scheme (batteries, power adapter, USB port) ensures the smooth operation of the meter.
| Model | Bante900P | 
| pH | |
| Range | -2.000 to 20.000 pH | 
| Resolution | 0.001 / 0.01 / 0.1 pH, selectable | 
| Accuracy | ±0.002 pH | 
| Calibration | 1 to 5 points | 
| pH Buffer Options | USA / NIST / DIN / 2 custom buffers | 
| ORP | |
| Range | -1999.9 to 1999.9 mV | 
| Resolution | 0.1 / 1 mV, selectable | 
| Accuracy | ±0.2 mV | 
| Calibration | 1 point | 
| Measurement Modes | Relative / Absolute mV | 
| Ion Concentration | |
| Range | 0.00 to 19999 (depending on the range of ISE) | 
| Resolution | 0.001, 0.01, 0.1, 1, automatic | 
| Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) | 
| Calibration | 2 to 5 points | 
| Calibration Solutions | 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000 | 
| Measurement Units | ppm, mg/L, mol/L, mmol/L | 
| Conductivity | |
| Range | 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm | 
| Resolution | 0.001, 0.01, 0.1, 1, automatic | 
| Accuracy | ±0.5% F.S. | 
| Calibration | 1 to 5 points | 
| Calibration Solutions | 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS | 
| Temperature Coefficient | 0.0 to 10.0%/°C | 
| Pure Water Compensation | Yes | 
| Reference Temperature | 20 / 25°C | 
| Cell Constant | K=0.1 / 1 / 10 / Custom | 
| TDS | |
| Range | 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt | 
| Resolution | 0.01, 0.1, 1, automatic | 
| Accuracy | ±1% F.S. | 
| TDS Conversion Factor | 0.1 to 1.0 (default 0.5) | 
| Salinity | |
| Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu | 
| Resolution | 0.01 | 
| Accuracy | ±1% F.S. | 
| Resistivity | |
| Range | 0.00 to 20.00 MΩ | 
| Resolution | 0.01 | 
| Accuracy | ±1% F.S. | 
| Dissolved Oxygen | |
| Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation | 
| Resolution | 0.01 / 0.1, selectable | 
| Accuracy | ±0.2 mg/L / ±2.0 % | 
| Calibration | 1 or 2 points | 
| Pressure Correction | 60.0 to 112.5 kPa / 450 to 850 mmHg, manual | 
| Salinity Correction | 0.0 to 50.0 g/L, manual | 
| Temperature | |
| Range | 0 to 105°C / 32 to 221°F | 
| Resolution | 0.1°C/°F | 
| Accuracy | ±0.5°C / ±0.9°F | 
| Calibration | 1 point | 
| Calibration Range | Reading ±10°C/°F | 
| Other Specifications | |
| Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic | 
| Hold Function | Manual / Auto-read measurement endpoint | 
| Stability Criteria | Low / High | 
| Calibration Due Alarm | 1 to 31 days or off | 
| Auto-Power Off | 10 / 20 / 30 minutes after last key pressed | 
| Memory | Stores up to 500 data sets | 
| Output | USB communication interface | 
| Connector | BNC, 6-pin mini-DIN, 3.5 mm jack socket | 
| Display | Custom LCD (80 × 60 mm) | 
| Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter | 
| Battery Life | Approximately 150 hours without backlight | 
| Environmental Conditions | 0 to 50°C / 32 to 122°F, relative humidity < 80% | 
| Dimensions | 170 × 85 × 30 mm | 
| Weight | 300 g | 
| Ordering Code | Meter Includes | 
| Bante900P-UK  | P11 glass pH electrode | 
| K10 conductivity electrode | |
| DO100 dissolved oxygen electrode | |
| TP-10K temperature probe | |
| pH 4.01, 7.00, 10.01 buffer reagents | |
| Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm | |
| DO electrolyte solution | |
| DO membrane cap | |
| Electrode clip | |
| Carrying case | 