Thrust force and Torque are measured simultaneously.
	Rated Output is adjusted at ±5V
	in both Mz and Fz direction.
	Just connect a sensor and apply 24V to it, then adjusted voltage will be outputted simultaneously.
	Any calibration settings are not required.
	
	 
| Model | Sensor : URT-20-5K Amplifier : FS200 | 
|---|---|
| Rated capacity | Mz : ±20Nm Fz : 5kN | 
| Power supply voltage | DC24V±15% | 
| Consumption current | 150mA or less | 
| Load signal output | Mz, Fz : ±5V | 
| Load resistance | 2kΩ or more | 
| Response | 2kHz | 
| I/O signal | 
				Input: Auto zero command Output: Auto zero response  | 
		
| Safe overload | Mz : 500%FS Fz : 400%FS | 
| Non-linearity | Mz : 0.1%FS typ. Fz : 0.5%FS | 
| Hysteresis | Mz : 0.1%FS typ. Fz : 0.5%FS | 
| Repeatability | Mz : 0.1%FS typ. Fz : 0.5%FS | 
| Cross talk | 
				Mz(20Nm) → Fz:0.05kN or less Fz(5kN) → Mz:0.2Nm or less  | 
		
| Compensated temp. range | 0 to +40℃ | 
| Safe temp. range | -10 to +50℃ | 
| Temp. effect on zero | 0.1%FS/℃ | 
| Temp. effect on span | 0.05%FS/℃ | 
| Sensor material | Stainless steel | 
| Weight | 
				Sensor:Approx. 250g, Amplifier:Approx. 180g (Excluding the cable)  | 
		
	*Above specifications are achieved when the sensor(URT-20-5K) is connected with the dedicated amplifier(FS200).
	*Accuracy is not guaranteed in the range of Fz 0 to -5V.
	 
	
	 
| 
				 
					Product catalogue(PDF) 
			 | 
			URT-20-5K catalogue(480 KB) | |
|---|---|---|
Malaysia