Honeywell S4560D1135 ignition control

Honeywell S4560D1135 ignition control

分类: Boiler & Burner Controller & Programmer 当前有货
欲了解更多详情,请游览我们的官方网站 enmarkengineering.com

Specifications
  • Product Details: Voltage: 220-240Vac, 50Hz Power consumption: 10 VA max
  • Honeywell S4560D1135 ignition control: Application: The S4560 provides automatic ignition and control for burners in accordance with EN 298. Specifications: Model S4560: 220-240 Vac, 50 Hz. Suffix A: For atmospheric burners. Nonvolatile lock out in accordance with EN 298. Suffix B: As suffix A except a built-in flame indication relay for modulating applications. Suffix C: For fan assisted applications. Nonvolatile lock out in accordance with EN 298. Suffix D: As suffix C except a built-in flame indication relay for modulating applications. Suffix E: As suffix A except lock--out after flame lost during normal operation. Suffix P: As suffix A except volatile lock out, reset by interrupting heat demand. Suffix Q: As suffix B except volatile lock out, reset by interrupting heat demand. Suffix R: As suffix C except volatile lock out, reset by interrupting heat demand. Suffix T: As suffix D except volatile lock out, reset by interrupting heat demand Ambient temperature 0-60 degree Celcius Relative humidity 90% max. at 40 degree Celcius (non condensing) Supply voltage Line voltage, 220 V (--15%) ... 240 V (+10%), 50 Hz ( 2 Hz) Power consumption: 10 VA max. Alarm output: 1 A max Flame indication relay: 1 A max External ignition transformer: 1 A max All outputs together: 3 A max Electrical connection High tension spark: 2.8 x 0.5 mm spade terminal. Flame rod and ground: 6.3 x 0.8 or 4.8 x 0.8 mm spade terminal (depending on O.S. number). Multiple connector: Molex 3001 series Timing (depending on O.S. number) Waiting time (Tw)/Prepurge time (Tp): 0-24 s Safety time (Ts): 0-250 s Stabilization time (Tstab): 0-15 s Flame sensing Flame sensing is based on the rectification principle. Minimum flame current: 0.7 ←A Response time ”ON”: < 200 ms (at 2 ←A flame current) Response time ”OFF”: < 1 s Maximum cable length: 1 m Not protected against electrical shock. Ignition Integral electronic spark generator Spark voltage: 12 kV at 40 pF load Repetition rate: 12 Hz Maximum cable length: 1 m Not protected against electrical shock
详情

Apologies, description is not available at the moment.

更多 ENMARK (M) SDN. BHD. 相关资料
ENMARK (M) SDN. BHD.
ENMARK (M) SDN. BHD. Instrumentation Control System Provider KL, Industrial Air Conditioning Installation Selangor, Dehumidification Control Supply Malaysia ~ ENMARK (M) SDN. BHD.