详情
Double ISO1 elpn 5/2 cable 2.5 m, 3w
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
770 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1050 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO1 elpn 5/2 servopil. cable 2.5 m, 3w
Double ISO1 elpn 5/2 servopil. cable 0.3 m, M8
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
770 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1050 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
vacuum |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO1 elpn 5/2 cable 0.3 m, M8
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
770 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1050 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO1 elpn 5/2 cable 2 m ATEX
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
770 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1050 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
45 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO1 elpn 5/2 servopil. cable 2 m ATEX
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
770 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1050 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
45 |
|
Min input pressure (bar) |
vacuum |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO2 elpn 5/2 cable 2.5 m, 3w
Double ISO2 elpn 5/2 cable 0.3 m, M8
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
1250 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1750 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO2 elpn 5/2 servopil. cable 2.5 m, 3w
Double ISO2 elpn 5/2 servopil. cable 0.3 m, M8
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
1250 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1750 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
vacuum |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO2 elpn 5/2 cable 2 m ATEX
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
1250 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1750 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
45 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO2 elpn 5/2 servopil. cable 2 m ATEX
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
1250 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
1750 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
45 |
|
Min input pressure (bar) |
vacuum |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO3 elpn 5/2 cable 2.5 m, 3w
Double ISO3 elpn 5/2 cable 0.3 m, M8
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
2500 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
3400 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO3 elpn 5/2 servopil. cable 2.5 m, 3w
Double ISO3 elpn 5/2 servopil. cable 0.3 m, M8
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
2500 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
3400 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
60 |
|
Min input pressure (bar) |
vacuum |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO3 elpn 5/2 cable 2 m ATEX
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
2500 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
3400 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
45 |
|
Min input pressure (bar) |
2.5 |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
Double ISO3 elpn 5/2 servopil. cable 2 m ATEX
|
Category - ISO EN 13849 |
4 |
|
Coils voltage |
24VDC - 24VAC - 110VAC - 220VAC 50/60 Hz |
|
DC |
High (>= 99%) |
|
Flow-rate at 6.3 bar DP 0.5 bar (Nl/min) |
2500 |
|
Flow-rate at 6.3 bar DP 1 bar (Nl/min) |
3400 |
|
Max input pressure (bar) |
010 |
|
Max temperature (°C) |
45 |
|
Min input pressure (bar) |
vacuum |
|
Min temperature (°C) |
-10 |
|
Way scheme |
double 5/2 |
更多 I Pneulic Industries Supply Sdn Bhd 相关资料