HIOKI DC HIPOT TESTER ST5680A

Category: Electrical Safety Testers , Hipot, Insulation, Leakage Testers Available
Purchasable on official site
For more information, visit our official website at accutac.com.my

Description

HIOKI DC HIPOT TESTER ST5680A
Bring Waveform Intelligence to Safety Testing.
Accelerate EV Battery Quality with DC Hipot Analysis.

Global Compliance & Unified Test Platforms

Standardize DC hipot testing across global EV battery sites with one platform.

  • CE, UKCA, and CSA (NRTL) certifications for worldwide use
  • Up to 8 kV/20 mA to satisfy standard defined DC withstand voltage tests
  • Easier global standardization of test recipes, criteria, and procedures

Built in Contact Check for Quality Improvement & Design Cost Reduction

Detect poor probing without external continuity hardware or complex sequences.

  • Capacitance based contact check built into the tester
  • Detects degradation or disconnection of jigs, leads, and high voltage relays
  • Reduces risk of false PASS due to poor contact on high value modules/packs
  • Simplifies wiring and PLC design, shortening line start up and debug time

Basic Specifications

Accuracy guaranteed: 1 year
For detailed measurement accuracy, temperature coefficients, and I/O signal assignments, refer to the instruction manual and brochure.
Main functions DC hipot test, Insulation resistance test, Breakdown voltage (BDV) test, Waveform display function, Arc detection, Contact check function
Operating temperature and humidity range 0°C to 40°C (32°F to 104°F), 80% RH or less (non-condensing)
Standards Safety: IEC 61010
EMC: EN 61326
Power supply 100 V to 240 V AC, 50 Hz/60 Hz
Power consumption Approx. 180 VA
(220 V, DC hipot test mode, 2.5 kV, 5 mA load current)
Maximum rated power 800 VA
Interface USB, LAN, EXT. I/O
Optional: RS-232C (Z3001), GP-IB (Z3000)
Memory: USB drive
Dimensions and mass Approx. 305 mm (12.01 in.) W × 142 mm (5.59 in.) H × 430 mm (16.93 in.) D (excluding protrusions)
Approx. 10.4 kg (366.8 oz.)
Included accessories Power cord ×1, EXT. I/O male connector ×1, EXT. I/O connector cover ×1, Interlock-canceling jig for EXT. I/O ×1, Startup Guide ×1, Operating Precautions (0990A903) ×1

Various Tests and Functionality

 
DC hipot test • Output voltage: 0.010 kV DC to 8.000 kV (1 V resolution)
• Output setting accuracy: ±20 V (below 3 kV, no load), ±0.4 % of setting ±8 V (3 kV and above, no load)
• Output/cutoff current: Max. 20 mA (test voltage 50 V or higher)
• Current accuracy: ±1.5% rdg. (typ., see instruction manual or brochure for details)
• Minimum resolution: 0.001 µA
• Test time: 0.1 s to 999 s, continuous (timer OFF)
• Voltage rise/fall time: 0.1 s to 300 s / 0.1 s to 300 s, OFF
• Test modes: W to IR, IR to W, Program test
Insulation resistance test • Output voltage: 10 V DC to 2000 V (1 V resolution)
• Output setting accuracy: ±20 V (no load)
• Resistance display range: 100.0 kΩ to 200.0 GΩ (0.01 kΩ resolution)
• Accuracy guarantee range: 100.0 kΩ to 99.99 GΩ
• Resistance accuracy: ±1.5% rdg. (see instruction manual or brochure for detailed range wise accuracy)
• Test time: 0.1 s to 999 s, continuous (timer OFF)
• Voltage rise/fall time: 0.1 s to 300 s / 0.1 s to 300 s, OFF
Breakdown voltage (BDV) test • Test methods: Continuous voltage rise test, Stepped voltage rise test
• Measurement: Insulation breakdown voltage (kV), Insulation breakdown strength (kV/mm)
• Settings: Start voltage, End voltage, Rise speed, Arc detection, Electrode distance, Upper limit current
Waveform display function • Waveforms: Voltage, Current, Insulation resistance
• Sampling rate: Max. 500 kS/s
• Display length: 0.5 s to 128 s (9 steps)
• Memory capacity: 512 k words
Arc detection • Detection method: Monitoring of test voltage fluctuations
• Setting range: Test voltage variability 1% to 50%
Contact check function • Detection method: Capacitance measurement method
• Setting range: Threshold (capacitance) setting 1.0 nF to 100.0 nF
Memory functions • Waveform / graph save:
Destination: USB memory
Formats: BMP, PNG, CSV

• Panel memory:
DC hipot/IR: up to 64 sets each
BDV test: up to 10 sets
Program test: up to 30 programs (max. 50 steps)

• Data memory:
Up to 32,000 measured values
Judgment functions • PASS, FAIL (UPPER FAIL, LOWER FAIL)
• Judgment output via EXT. I/O and communication
Safety and usability functions • Interlock: links output enable/disable with external safety devices
• Automatic discharge: internal discharge after testing (residual voltage 30 V or less)
• Voltage limitation:upper limit control from 0.010 kV to 8.000 kV
• Auto range: automatic range switching based on measured values
• Panel memories: store and recall test conditions
• Self check/Key lock/Command monitor/I/O HANDLER test

More detail about Accutac Sdn Bhd
Accutac Sdn Bhd
Accutac Sdn Bhd Thermal Imager Supplier Penang, Data Logger, LCR Meter Supply Malaysia, Power Quality Meter, Precision Measuring Instruments Supplies Bayan Lepas ~ Accutac Sdn Bhd
Contact Us flagMalaysia