Features
| Model | i-14150W | ||
|---|---|---|---|
| Items | Unit | ||
| Power frequency | Hz | 50 / 60 | |
| Power source voltage | V | 400 | |
| Free air delivery | m3/min | 25.0 (25.9)* | |
| Delivered air pressure | MPa | 0.7 (0.39)* | |
| Pressure control method | Constant pressure control by inverter | ||
| Intake air pressure& temperature | Atmospheric pressure (2~40℃) | ||
| Main motor power | kW | 150 | |
| Motor type | Totally enclosed fun cooled IPM motor | ||
| Starter | Inverter starter | ||
| Drive system | Direct coupled motor | ||
| Cooling system | Water cooled | ||
| Fan motor power | kW | 0.15 / 0.22 | |
| Lubrication water amount | L | 135 | |
| Cooling water volume (water temp.32℃) |
L/min | 300 | |
| Dryer | Air dew point at outlet | ℃ | Installed separately (option) |
| Refrigerator power | kW | ||
| Discharge pipe diameter | R | JIS 10k 4B (100A) flange | |
| Total mass (dry 0鹢ut dryer) | kg | 2,400 | |
| Noise level [OP1.5m] | dB0鸄 | 66 ~ 70 | |
| W×L×H(body0鹢ut dryer) | mm | 2750×1200×1800 | |
Cautions:Dryer of low-pressure specifications(factory option)shall be a separate type. Please contact us for dryer dimensions and mass.
Values in ( )* are the free air delivery for 0.39 MPa specification(factory option)
◎for 55 kW / 75 kW air-cooled devices, a separately installed cooler unit(1560×1115×1500(W×L×H)/ 585 kg(mass)is included in addition to the main unit.
◎Noise values measured in a noiseless environment at a distance of 1.5 m from the front, at height of 1 m, with a load of 60 to 100%(at 0.7 MPa)
Malaysia