Specifications
            
                
                - Ultrasonic Flowmeter UFW-100: Specifications
Measurement	Method	Ultrasonic pulse transit time difference method
Diameter Range	DN 25mm - 600mm
Accuracy	Pipe Diameter	Velocity  1m/s	Velocity < 1m/s
DN 25mm - 40mm (*1)	±2.5% R.D.	±0.025m/s
DN 50mm - 90mm	±2.0% R.D.	±0.020m/s
DN 100mm - 250mm	±1.5% R.D.	±0.015m/s
DN 300mm - 600mm	±1.0% R.D.	±0.010m/s
Output	Analog output	1port(Std.)       4-20mA  Allowable load resistance 600Ω Max.
Relay output	1port(Std.)       for Totalizing, Warning or Directional output
Digital output	1port(Std.)       USB connection / Inter-communication mode
1port(Option)   RS-485 / MODBUS-RTU output
Input	Analog Input	1port(Option)   4-20 mA / Passive input
Main unit	Protection Degree	IEC60529 IP65
Transducer	Applicable Temperature	20 ~ 60℃
Protection Degree	IEC60529 IP65(Std.) / IEC60529 IP67(Option)
Cable Length	30m Max. (Applicable cable model : RG-223U)
Data Logging	Over 68,000 lines(exp. more than 1month by 1min interval / Interval selectable)
Logged Item; Date, time, Instantaneous flow rate, +Total, -Total, Error code and Event status
Function	PC Graphical parameter setting
4 key configurable from the console
Self-diagnostics
Disturbance detection
No Echo receiving warning
Low flow cut
Zero shift	Span compensation
Fixed Analog Output
Auto Gain Control
Preset Totalize Start
Data Retention
Echo-wave form monitor
Error Status indication
 
        
        Description
        Ultrasonic Flowmeter UFW-100 Now Comes, Measurement Unlimited by the Imagination.
TOKYO KEIKI, the world’s first supplier of ultrasonic flowmeters and industry pioneer is proud to introduce the clamp-on flowmeters of next generation which are environmentally friendly and provide the consistent reliability and “Made in Japan”quality that customers have come to expect from the TOKYO KEIKI brand.
The new UFW-100 Series ultrasonic flowmeter boasts a smaller, more compact footprint & size and lower power consumption in a material-saving, RoHS compliant design.
<Advantage of "Clamp-On"> 
No Pressure Loss (pump power savings)
No Wetted Parts (no contact with liquid)
No Moving Parts (no wear)
No Need to Stop the Process (easy installation)
<Typical Application> 
Water Distribution
Factory Utilities
HVAC Systems
Process Monitoring
Replacement for old in-line meters
Desalination Processes
<Main Functions and Features> 
Measuring Accuracy : +/- 1.0~2.5% of reading
4-20mA Output (1ch)
Contact Output (1ch)
Data Logging (1min. intervals; up to 1month)
RS-485 Modbus Output (1ch) (Option)
Analog Current Input (1ch) (Option)
Smaller, Compact Footprint & Size*1
Lower Power Consumption *2
RoHS Compliant