Accumulator P Series
P series accumulator is installed between the suction port of the refrigerating system compressor and evaporator to separate gas and fluid, store fluid, return oil and filter.
.png) Size L x W x H = 50 x 16 x 16 (cm)
 Size L x W x H = 50 x 16 x 16 (cm).png) Inlet and outlet are made of copper tubes
 Inlet and outlet are made of copper tubes.png) The air guiding part direct the refrigerant toward the wall which forms a slipstream to make the refrigerant expand quickly and slow the flow to let the liquid drop down. This effectively separates the liquid and gas
 The air guiding part direct the refrigerant toward the wall which forms a slipstream to make the refrigerant expand quickly and slow the flow to let the liquid drop down. This effectively separates the liquid and gas.png) The U tube design guarantees a max flow of refrigerant and stops little lubrication oil. The inlet of U tube is behind air guiding part which can prevent the liquid from entering the compressor. At the same time, it can change the direction of refrigerant to completely separate        the liquid and gas
 The U tube design guarantees a max flow of refrigerant and stops little lubrication oil. The inlet of U tube is behind air guiding part which can prevent the liquid from entering the compressor. At the same time, it can change the direction of refrigerant to completely separate        the liquid and gas.png) The balancing hole in the upper U tube can effectively eliminate the siphon caused the restart of the system so as to avoid excessive          liquid entering the compressor
 The balancing hole in the upper U tube can effectively eliminate the siphon caused the restart of the system so as to avoid excessive          liquid entering the compressor.png) The oil return hole is matching the system capacity to optimize the flow of liquid refrigerant and lubrication oil into the compressor
 The oil return hole is matching the system capacity to optimize the flow of liquid refrigerant and lubrication oil into the compressor.png) Connection tube, U tube, and volume of the accumulator is designed based on the basic demand of Heat pump system including safety store capacity (vs. total capacity); protective flow control back to compressor allows a proper and reliable liquid refrigerant and lubrication oil back to the compressor. This combination is to achieve a minimum pressure drop and largest refrigerant capacity
 Connection tube, U tube, and volume of the accumulator is designed based on the basic demand of Heat pump system including safety store capacity (vs. total capacity); protective flow control back to compressor allows a proper and reliable liquid refrigerant and lubrication oil back to the compressor. This combination is to achieve a minimum pressure drop and largest refrigerant capacity.png) Powder coated surface can survive 500hours of salt spray test
 Powder coated surface can survive 500hours of salt spray test.png) The incorporated fuse of 430F
 The incorporated fuse of 430F.png) Applicable refrigerant: CFC, HCFC, HFC etc.
 Applicable refrigerant: CFC, HCFC, HFC etc..png) Applicable medium temperature: -30°C to +120°C (-22°F to 240°F)
 Applicable medium temperature: -30°C to +120°C (-22°F to 240°F).png) Applicable ambient temperature: -35°C to +55°C (-22°F to 131°F)
 Applicable ambient temperature: -35°C to +55°C (-22°F to 131°F).png) Maximum working pressure: 2.5MPa
 Maximum working pressure: 2.5MPa.png) Certification: UL, CSA, and PED
 Certification: UL, CSA, and PED