Cooling Tower & HVAC System Maintenance
Cooling Tower & HVAC System Maintenance

 13

Cooling Tower & HVAC System Maintenance

On 17 January 2026, the technical team from EKG (Malaysia) Sdn Bhd carried out comprehensive HVAC and cooling system maintenance. The works focused on improving system efficiency, restoring equipment performance, and extending the operational life of the cooling tower and associated units.

The maintenance activities included:

1. Replace 25HP Compressor

The existing compressor was removed and replaced with a new 25HP compressor to restore full cooling capacity. Proper installation and testing ensured optimal performance, efficiency, and system reliability.

2. Scaling Removal on Unit Condenser

The unit condenser was inspected and cleaned to remove mineral scaling and deposits that reduce heat transfer efficiency. Chemical and mechanical cleaning restored proper condenser performance, helping maintain energy efficiency and prolonging equipment life.

3. Chemical Cleaning of Cooling Coil

The cooling coil underwent chemical cleaning to remove dirt, algae, and debris buildup. This process enhances heat exchange efficiency, improves airflow, and ensures consistent cooling performance.

4. Replacement of Faulty Valves

Worn or malfunctioning valves were replaced to maintain precise flow control throughout the system. Properly functioning valves ensure balanced water distribution, prevent leaks, and support overall HVAC efficiency.

5. Replacement of Pressure Switches

Faulty pressure switches were replaced to ensure accurate system monitoring and protection. Proper pressure switch operation prevents overloading, improves safety, and maintains reliable system operation.

Importance in Preventive HVAC Maintenance

These maintenance activities are critical for the long-term performance of cooling towers and HVAC systems. Timely replacement of key components, scaling removal, and cleaning helps reduce energy consumption, prevent breakdowns, and maintain consistent cooling performance.

Professional Execution

At EKG (Malaysia) Sdn Bhd, all maintenance works, including compressor replacement, condenser scaling removal, cooling coil cleaning, valve replacement, and pressure switch replacement, are carried out with precision and attention to system reliability. Each task is executed to ensure efficient operation and long-term durability of the HVAC system.
 