Fire Damper Integrated AHU Installation

Fire Damper Integrated AHU Installation

Kategori: BOMBA Certified AHU Installation Tersedia
Untuk informasi lebih lanjut, kunjungi situs resmi kami di eakon.com.my

Deskripsi

Fire Damper Integrated AHU Installation: 2026 Statutory Standards

In the 2026 Malaysian regulatory environment, a Fire Damper Integrated AHU Installation is a critical engineering requirement for building safety. Under the Fire Services Act 1988 (Act 341) and the Uniform Building By-Laws (UBBL) 2026, fire dampers are mandatory wherever ductwork penetrates a fire-rated wall or floor slab. This integration ensures that the AHU system does not facilitate the spread of flame and toxic smoke between fire compartments.

At EKG (Malaysia) SDN BHD, we treat the damper-to-AHU interface as a primary life-safety junction, ensuring your installation is Sterile, Silent, and Statutory-Compliant.


1. The Statutory Mandate: BOMBA "K" Mark Compliance

To obtain an AHU Safety Permit, all integrated fire dampers must be certified and auditable.


2. Engineering the Integration

A "Fire Damper Integrated" setup requires precision at the point of penetration to maintain the wall's fire rating.


3. Installation Benchmarks & Materiality

Component 2026 Technical Requirement Engineering Purpose
Intumescent Fire-Stop BOMBA-approved mastic/mortar Seals the gap between the damper sleeve and the wall.
Sleeve Gauge Minimum 1.6mm (16 GA) Provides structural integrity during extreme heat.
Access Door Minimum 450mm x 450mm Required for mandatory periodic inspection of the damper blades.
Fail-Safe Actuator Spring-Return (24V/230V) Automatically closes the damper upon loss of power.

4. Verification & Functional Testing

Before commissioning, EKG engineers perform a dual-validation witness test:

  1. The "Cold" Test: Verification that the damper blades rotate freely and that the Duct Smoke Detector triggers the motorized actuator.

  2. The "Interlock" Test: Confirmation that the AHU motor shuts down immediately upon damper closure to protect the integrity of the ductwork and the TB2 Thermal Break casing.

  3. Passive Audit: Inspection of the fire-stop mortar to ensure a smoke-tight seal around the penetration.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your fire damper integration safe enough for a 2026 audit? Contact EKG (Malaysia) SDN BHD today for a specialized Fire Damper & AHU Integration Audit.

Are you installing these dampers for a new commercial high-rise or as part of a fire-safety retrofit for an existing facility?