Deskripsi
Schneider Electric PowerLogic ION9000 / PM9000 Series
PowerLogic ION9000 Series Advanced Power Quality Meters
Schneider Electric PowerLogic ION9000 Series meters are advanced power quality meters for critical electrical networks where power quality, revenue accuracy, disturbance analysis, compliance reporting and cybersecurity are important.
The ION9000 / PM9000 Series is suitable for data centres, semiconductor plants, hospitals, airports, utilities, large manufacturing facilities, oil and gas plants, water treatment plants, campuses and mission-critical LV, MV and HV systems.
Class 0.1 / 0.1S Accuracy
IEC 61000-4-30 Class A
IEC 62586 PQI
Waveform Capture
Disturbance Direction Detection
ION9000T HSTC Option
IoTWatt 4.0 Ready
Product Overview
The PowerLogic ION9000 Series provides continuous, high-precision power quality and energy monitoring. It goes beyond normal multi-function metering by capturing disturbances, waveforms, sags, swells, harmonics, transients, event logs and compliance-related power quality information.
The ION9000 is suitable where electrical data must be trusted for critical operational decisions, power quality investigations, cost allocation, billing-quality review, root cause analysis and long-term network performance tracking.
Positioning: ION9000 is the advanced power quality and revenue-grade metering platform. ION9000T adds high-speed transient capture for demanding diagnostic applications.
Why ION9000 Matters
In critical electrical networks, it is not enough to know that an event happened. Engineering teams need to know when it happened, how severe it was, where it came from and what equipment was affected.
- Sag / swell visibility
- Transient investigation
- Waveform evidence
- Harmonic analysis
- Event timestamping
- Compliance reporting
- Root cause support
Typical Power Quality Monitoring Architecture
ION9000 meters are installed at critical electrical points and connected through Ethernet or RS485 to EcoStruxure Power Monitoring Expert, SCADA, EMS, BMS, utility systems or IoTWatt 4.0.
1
LV / MV / HV Point
Critical incoming or feeder location.
2
ION9000 Meter
High-accuracy PQ and energy capture.
3
PQ Event Capture
Sag, swell, transient, waveform and logs.
4
PME / SCADA / IoTWatt
Dashboards, alarms and reporting.
5
Root Cause
Engineering review and corrective action.
Key Features at a Glance
IEC 61000-4-30 Class A
Class A power quality measurement for compliance-grade monitoring.
IEC 62586 PQI
Power Quality Instrument performance for reliable PQ applications.
Class 0.1 / 0.1S Accuracy
High-accuracy energy and power measurement for critical decisions.
Disturbance Direction Detection
Helps identify whether an event is upstream or downstream.
Waveform Capture
Records voltage and current waveform evidence during events.
ION9000T HSTC
High-Speed Transient Capture for very fast voltage events.
Advanced Harmonics
Supports harmonic visibility for nonlinear load and compliance review.
Large Onboard Memory
Stores logs, waveform records, event records and PQ history.
Cybersecurity Features
User access control, secure communication and audit logging support.
ION9000 vs ION9000T
| Feature |
ION9000 |
ION9000T |
| Typical Use |
Advanced power quality, revenue-grade metering, compliance monitoring and critical network visibility. |
All ION9000 functions plus high-speed transient diagnostics for very fast voltage events. |
| Energy Accuracy |
ANSI Class 0.1 / IEC Class 0.1S active energy accuracy. |
ANSI Class 0.1 / IEC Class 0.1S active energy accuracy. |
| Power Quality |
IEC 61000-4-30 Class A and IEC 62586 PQI applications. |
IEC 61000-4-30 Class A and IEC 62586 PQI applications. |
| Waveform Capture |
High-resolution waveform capture for voltage and current event analysis. |
High-resolution waveform capture plus enhanced transient diagnostics. |
| Transient Capture |
Advanced PQ event and waveform capture. |
High-Speed Transient Capture for very fast impulsive and oscillatory events. |
| Best Fit |
Main incomers, utility points, critical feeders, large energy users and compliance monitoring. |
Data centres, semiconductor plants, sensitive electronics, process plants and severe transient investigations. |
Commercial Reference Numbers and Variant Selection
| Commercial Reference |
Variant / Description |
Recommended Use |
| METSEION92030 |
ION9000 meter, DIN mount, no display, hardware kit. |
Remote monitoring through PME, SCADA, EMS, BMS or IoTWatt 4.0. |
| METSEION92040 |
ION9000 meter, DIN mount, 192 mm display, B2B adapter, hardware kit. |
Critical panels where local operator visibility is required. |
| METSEION92043 |
ION9000 meter, 192 mm display, Measurement Canada Ready. |
Canada-specific metering applications requiring Measurement Canada readiness. |
| METSEION92044 |
ION9000 meter, 192 mm display, Measurement Canada sealed. |
Canada-specific installations requiring sealed metering configuration. |
| METSEION92130 |
ION9000 meter, 20 60 Vdc control input, DIN mount, no display. |
Substations, protection panels and DC control power systems. |
| METSEION92140 |
ION9000 meter, 20 60 Vdc control input, 192 mm display. |
Sites requiring both DC control power and local display. |
| METSEION93030 |
ION9000 meter, LVCS, DIN mount, no display. |
Low-voltage current sensor architecture without local display. |
| METSEION93040 |
ION9000 meter, LVCS, 192 mm display. |
LVCS installations requiring local display and advanced PQ monitoring. |
| METSEION93130 |
ION9000 meter, LVCS, 20 60 Vdc control power, no display. |
DC control power panels using LVCS current sensor architecture. |
| METSEION93140 |
ION9000 meter, LVCS, 20 60 Vdc control power, 192 mm display. |
Where LVCS, DC control power and local display are all required. |
| METSEION95030 |
ION9000T meter, HSTC, DIN mount, no display. |
High-speed transient capture for data centres, semiconductor and sensitive processes. |
| METSEION95040 |
ION9000T meter, HSTC, 192 mm display. |
Critical PQ installations requiring local event visibility and transient diagnostics. |
Selection note: Use ION9000 for advanced Class A power quality monitoring, revenue-grade metering, waveform capture and disturbance analysis. Use ION9000T when very fast transient capture is required.
Accessories and Option Modules
| Commercial Reference |
Accessory / Module |
Purpose |
| METSERD192 |
Remote display, colour touchscreen, 192 mm x 192 mm. |
Large local display for panel-front operation and PQ visibility. |
| METSEPM89RD96 |
Remote display, colour LCD, 96 mm x 96 mm. |
Smaller display option where a 96 mm meter-style display is preferred. |
| METSEPM89M2600 |
I/O module, 2 relay outputs, 6 digital inputs. |
Additional digital inputs and relay outputs for alarms, status and signals. |
| METSEPM89M0024 |
I/O module, 2 analog outputs, 4 analog inputs. |
Analog signal integration for process or external measurement points. |
| METSEPMRS4854W |
4-wire RS485 option module. |
Adds 4-wire RS485 communication capability. |
| METSEPMFIBER |
Fiber-Ethernet option module. |
Fiber Ethernet communication for isolation or long-distance communication. |
| METSE9HWK |
ION9000 meter hardware kit. |
Installation or replacement hardware kit. |
| METSE9CTHWK |
ION9000 current input hardware kit. |
Current input terminal screws and CT covers. |
| METSE9B2BMA |
ION9000 B2B mounting adapter. |
Back-to-back mounting adapter for 192 mm display installations. |
| METSE9HWKLVCS |
ION9000 hardware kit for LVCS. |
Hardware kit for LVCS current input variants. |
Advanced Power Quality Functions
Sag / Swell Detection
Captures voltage dips and rises with magnitude and duration information.
Disturbance Direction Detection
Helps separate utility-side events from internal plant-side events.
Waveform Capture
Records event waveforms for engineering evidence and troubleshooting.
Transient Capture
ION9000T supports investigation of very fast impulsive and oscillatory events.
Harmonic Measurement
Supports harmonic compliance review, filter design and nonlinear load investigation.
Sequence of Events
Records events with accurate timestamps for forensic analysis.
Applications and Best-Fit Sites
- Data centres
- Semiconductor plants
- Hospitals
- Airports
- Utilities
- Oil and gas facilities
- Water treatment plants
- Large manufacturing facilities
- Critical infrastructure
- Campuses
- MV / LV incomers
- UPS feeders
- Critical loads
- Power quality compliance points
Integration with IoTWatt 4.0
IoTWatt 4.0 can use ION9000 meter data as a high-quality power quality and energy data source for critical sites that require continuous PQ visibility together with energy performance monitoring, demand analytics, EECA reporting and savings verification.
- kWh and demand monitoring
- Voltage and current trends
- Power factor monitoring
- Harmonic dashboards
- PQ event timeline
- Sag / swell review
- Transient event visibility
- Equipment trip correlation
- Digital energy audit evidence
- EECA reporting support
Quick Selection Guide by Application
| Application Requirement |
Recommended Direction |
Reason |
| Remote monitoring only |
ION9000 no-display model |
Best where monitoring is fully remote through software or IoTWatt 4.0. |
| Local touchscreen display required |
ION9000 with 192 mm display |
Provides panel-front visibility for operators and engineers. |
| Low-voltage DC control power required |
20 60 Vdc control input variant |
Suitable for substations and DC auxiliary power architectures. |
| Low-voltage current sensor input required |
LVCS variant |
For low-voltage current sensor measurement architecture. |
| Very fast transient capture required |
ION9000T HSTC variant |
Best for semiconductor, data centre and sensitive process applications. |
| Fiber communication required |
Fiber Ethernet option module |
Useful for long-distance or electrically isolated communication. |
| Additional I/O required |
Digital or analog I/O option module |
Supports alarms, status, external signals and automation integration. |
Recommended Deployment Checklist
- Confirm PQ objective
- Select ION9000 or ION9000T
- Confirm installation point
- Confirm voltage level
- Confirm CT / PT / VT data
- Select display type
- Confirm control power
- Confirm Ethernet / RS485 / fiber
- Confirm cybersecurity requirements
- Confirm PQ reporting standard
- Confirm waveform and event retrieval
- Test time synchronisation
- Test alarms and logs
- Integrate with PME / SCADA / IoTWatt
ION9000 / PM9000 Supply, Commissioning and IoTWatt 4.0 Integration
Saturn Pyro supports Schneider Electric PowerLogic ION9000 / PM9000 Series advanced power quality meters for critical power monitoring, Class A PQ measurement, transient capture, disturbance direction detection, waveform recording, compliance reporting, EMS / BMS / SCADA integration and IoTWatt 4.0 digital energy audit projects in Malaysia.
Enquire Now
Lihat detail lebih lanjut tentang Saturn Pyro Sdn Bhd