Deskripsi
Powerside Portable Class A Power Quality Analyzer
PQube 3 Portable Power Quality Analyzer
The Powerside PQube 3 Portable combines the monitoring, recording and communication capability of the PQube 3 Power Analyzer with a quick-install portable package. It is designed for temporary power quality investigations, site troubleshooting, commissioning, energy studies, FAT support and critical equipment monitoring.
With flexible CTs, fused voltage leads and automatic detection of mains frequency, nominal voltage and wiring configuration, the PQube 3 Portable can be deployed quickly at low-voltage switchboards, machine feeders, UPS outputs, distribution boards and temporary monitoring points.
IEC 61000-4-30 Class A
Portable Field Kit
Flexible CTs
4MHz Impulse Detection
2kHz-150kHz Conducted Emissions
IoTWatt 4.0 Ready
PQube 3 Portable
Temporary Class A PQ monitoring kit for field engineers
Voltage Leads
Fused voltage leads with alligator clips for temporary connection.
Current Sensors
Flexible CTs for large feeder and busbar measurements.
Data Access
USB download or network reporting when connected.
Event Evidence
Waveforms, RMS graphs, reports and disturbance records.
Power Quality
IEC 61000-4-30 Class A monitoring for serious investigation work
Portable Kit
Flexible CTs, fused voltage leads and carrying case for field use
High-Frequency Events
4MHz impulse detection and 2kHz-150kHz conducted emissions
Reporting
USB download, network access, event reports and scheduled reports
Overview: Temporary Class A PQ Investigation
PQube 3 Portable is used where a permanent analyser is not required or where the monitoring point changes from site to site. It gives engineers a practical way to capture voltage sags, swells, interruptions, harmonics, transients, conducted emissions, energy consumption and load behaviour during a defined investigation period.
It can operate as a standalone logger using USB for configuration and data download. When connected to a network, it can send event notifications and daily, weekly or monthly reports directly to users, helping reduce repeated site visits and manual data extraction.
Key positioning
PQube 3 Portable is best positioned as a portable Class A power quality analyser for fast deployment, temporary monitoring, troubleshooting, commissioning support and engineering investigation.
How PQube 3 Portable Supports Investigations
Power quality events are often intermittent. PQube 3 Portable helps engineers leave the analyser at site long enough to capture the real event, then convert the evidence into a useful report.
1. Deploy
Install fused voltage leads and flexible CTs at the selected monitoring point.
2. Auto Detect
Detect nominal voltage, frequency and wiring configuration.
3. Record
Capture sags, swells, interruptions, harmonics, transients and energy trends.
4. Report
Download by USB or receive event and scheduled reports over network.
5. Act
Use evidence for root-cause analysis, corrective action and monitoring plan.
Key Benefits
FAST
Quick Installation
Designed for fast connection using flexible CTs and fused voltage leads with alligator clips.
AUTO
Auto-Detection
Automatically detects frequency, nominal voltage and wiring configuration to reduce setup time.
A
Class A PQ Monitoring
Supports IEC 61000-4-30 Class A power quality monitoring for serious investigation work.
4M
Transient Capture
Detects high-frequency transients and impulse events up to 4MHz.
150k
Supraharmonics
Records conducted emissions in the 2kHz to 150kHz range.
USB
Standalone or Networked
Use standalone with USB storage or connect to a network for remote reports and notifications.
Power Quality and Energy Monitoring
PQube 3 Portable provides high-quality power event recording and energy visibility. It is suitable for identifying whether supply events are causing equipment trips, control faults, production interruption, UPS transfer events or unexplained process issues.
| Monitoring Area |
Capability |
Practical Value |
| Voltage Events |
Records sags, dips, swells, interruptions and rapid voltage changes. |
Identify supply disturbances linked to machine trips, PLC resets or UPS transfers. |
| Waveform Capture |
Records waveforms and RMS graphs for event analysis. |
Provides evidence for troubleshooting reports, OEM discussions and customer reporting. |
| Harmonics and THD |
Measures voltage and current harmonics, THD, TDD and distortion trends. |
Supports harmonic investigation and power quality improvement studies. |
| High-Frequency Transients |
Detects impulse events up to 4MHz. |
Helps identify fast events that may disturb sensitive electronics. |
| Conducted Emissions |
Records 2kHz to 150kHz conducted emissions. |
Useful for supraharmonic and inverter / power electronics related investigations. |
| Energy and Demand |
Monitors power, energy, demand, power factor and load profile behaviour. |
Supports temporary energy studies and equipment-level consumption analysis. |
Portable Kit Contents
The PQube 3 Portable package is intended for field engineers who need to move the analyser between locations. The kit includes the analyser package, current sensors, fused voltage leads and carrying case for practical site deployment.
| Included Item |
Description |
Purpose |
| Flexible CTs |
Four flexible 3000A rated CTs |
Quick current measurement on feeders, busbars or large cables. |
| Split-Core CT |
One 5A split-core CT |
Additional current measurement or auxiliary channel use. |
| Fused Voltage Leads |
Voltage leads with alligator clips |
Safer temporary voltage connection during field measurement. |
| Carrying Case |
Portable field carrying case |
Protects the instrument and accessories during transport. |
| USB Storage Support |
USB stick can be used for configuration and data download |
Allows standalone operation when network access is not available. |
Field safety note
For temporary monitoring, always confirm voltage category, PPE requirements, safe access, fused lead connection method, CT placement and switching procedure before installation.
Technical Highlights
| Parameter |
Specification / Capability |
| Product Type |
Portable PQube 3 Class A power quality analyser package |
| Installation Type |
Temporary / portable installation using flexible CTs and fused voltage cables |
| Voltage Range |
100 to 480Vac nominal for the portable package |
| Self-Powered Operation |
Self-powers from measured voltage in the 360 to 480Vac range |
| Alternative Instrument Power |
24Vdc or external transformer 120 to 240Vac |
| Current Range |
0 to 3000A using flexible CTs |
| Power Quality Class |
IEC 61000-4-30 Class A, Edition 3 |
| Energy Accuracy |
Class 0.2 kWh accuracy, depending on sensor and configuration |
| High-Frequency Transients |
Detects high-frequency transients at 4MHz |
| Conducted Emissions |
Records 2kHz to 150kHz conducted emissions |
| Analogue Inputs |
Four additional AC/DC analogue inputs for DC or process monitoring |
| Environmental Probes |
Optional two environment probes for temperature, humidity, barometric pressure and acceleration |
| Battery Backup |
Up to 1 hour battery backup |
| Storage / Data Access |
USB configuration and data download; network reporting when connected |
| Dimensions |
Approximately 8.5 x 6 x 12 in / 21.59 x 15.24 x 30.48 cm |
| Weight |
Approximately 10 lb / 4.5 kg |
Typical Applications
Power Quality Investigation
Deploy at problem feeders or machines to capture sags, swells, interruptions and waveform events.
Manufacturing Troubleshooting
Identify supply-related causes of machine trips, VFD faults, PLC resets and nuisance stoppages.
Data Centre and UPS Checks
Monitor UPS input / output, PDU feeders and critical supply points during investigations.
Commissioning and FAT
Use during commissioning, temporary verification and factory acceptance testing of electrical systems.
Energy Audit Support
Capture temporary load profile, demand, power factor and energy data for audit and analysis work.
Inverter and Power Electronics
Investigate harmonics, supraharmonics and conducted emissions from drives, UPS and converter systems.
Standalone and Network Operation
PQube 3 Portable can be used as a standalone field analyser where network access is not available. Engineers can configure the unit and download data using a USB stick. Where Ethernet or network access is available, the analyser can send event notifications and scheduled reports automatically.
- Standalone operation using USB stick for configuration and data download.
- Network operation for remote access and automatic reporting.
- Event notifications after power quality disturbances.
- Daily, weekly and monthly reports when connected.
- Useful for temporary deployment at multiple customer or site locations.
USB Data Download
Network Reports
Email Notifications
Event Waveforms
Scheduled Reports
Temporary Site Monitoring
Why Use PQube 3 Portable?
Many power quality problems are intermittent. They may not happen during a short site visit, and they may not be captured by normal power meters. PQube 3 Portable gives engineers a practical way to leave a Class A analyser at site long enough to capture the real event.
- Faster deployment compared with permanent panel installation.
- Captures real power quality events during normal operation.
- Provides waveform evidence instead of assumptions.
- Supports power quality, energy and environmental correlation.
- Can be moved between different sites or feeders.
- Useful before deciding on permanent PQ monitoring points.
Integration with IoTWatt 4.0 and Monitoring Systems
PQube 3 Portable can be used together with IoTWatt 4.0 during power quality investigations and temporary monitoring projects. PQube 3 provides high-resolution PQ event data, while IoTWatt 4.0 can provide energy dashboards, equipment trends, tickets and longer-term operational context.
- Use PQube 3 Portable for temporary high-resolution event capture.
- Use IoTWatt 4.0 for ongoing energy and equipment analytics.
- Correlate PQ events with production, energy and operational behaviour.
- Support energy audits, EECA reporting and power quality investigations.
- Convert investigation findings into permanent monitoring recommendations.
Practical workflow with IoTWatt 4.0
Deploy PQube 3 Portable to capture the disturbance evidence, use IoTWatt 4.0 to understand operational and energy context, then convert the findings into corrective actions, monitoring dashboards and follow-up improvement projects.
Recommended Deployment Checklist
- Confirm the voltage system, wiring configuration and monitoring objective.
- Confirm CT range, CT placement and feeder access before site work.
- Confirm temporary voltage lead connection points and safety isolation requirements.
- Confirm the monitoring duration required to capture intermittent events.
- Decide whether standalone USB operation or network reporting is required.
- Record site operating conditions during the monitoring period for event correlation.
- Review waveform records, RMS trends, harmonic levels, conducted emissions and energy profile after retrieval.
PQube 3 Portable Supply and Investigation Support
Saturn Pyro supports Powerside PQube 3 Portable power quality analyser applications for manufacturing plants, data centres, semiconductor facilities, utilities, commercial buildings, energy audits, temporary power quality investigations and IoTWatt 4.0 monitoring projects in Malaysia.
Enquire Now
Lihat detail lebih lanjut tentang Saturn Pyro Sdn Bhd