Deskripsi
Powerside Class A Power Quality Analyzer
PQube 3 Power Quality Analyzer
Powerside PQube 3 is a compact Class A power quality analyser, revenue-grade energy meter and real-time power monitoring platform for critical electrical systems.
It records power quality disturbances, energy use, high-frequency events, harmonics, supraharmonics, environmental data and process parameters in one integrated device. It works like a black box for the electrical system, capturing what happened, when it happened and how the system responded.
IEC 61000-4-30 Class A
Class 0.2 kWh Accuracy
512 Samples / Cycle
Impulse Detection up to 4MHz
2kHz to 150kHz Supraharmonics
Web + Email Reports
IoTWatt 4.0 Ready
Product Overview
PQube 3 is designed for critical facilities and industrial sites where power quality events can cause trips, downtime, damaged equipment, nuisance faults or production losses. It provides compliant power quality measurements, waveform capture, event reports and long-term trend information.
It is suitable for manufacturing plants, semiconductor facilities, data centres, hospitals, utilities, commercial buildings, airports, water infrastructure, renewable energy systems, UPS systems and other critical electrical installations.
Positioning: Class A power quality analyser, energy meter, transient recorder and environmental monitoring platform for critical electrical systems.
Why PQube 3 Matters
Many sites only know that equipment tripped. PQube 3 helps show whether the event was caused by voltage sag, swell, interruption, transient, harmonics, frequency shift, external utility condition or internal site behaviour.
- Power event black box
- Root-cause evidence
- Class A compliance
- Waveform capture
- Energy monitoring
- Automated reports
- Critical facility visibility
Typical Monitoring Workflow
PQube 3 continuously monitors the electrical network, records disturbances, creates event files and reports, and makes the information available through web access, email, industrial protocols or monitoring platforms.
1
Electrical Point
Incomer, feeder, UPS, PDU or critical load.
2
PQube 3
Class A PQ and energy monitoring.
3
Event Capture
Waveforms, RMS, trends and reports.
4
Web / Email / Protocols
Data access and system integration.
5
Action
Investigation, mitigation and reporting.
Key Features at a Glance
Class A Power Quality
Compliant with IEC 61000-4-30 Class A power quality measurement requirements.
Revenue-Grade Energy
Provides Class 0.2 kWh accuracy for high-precision energy and power monitoring.
High-Speed Recording
512 samples per cycle for Class A power quality recording at 50Hz and 60Hz.
HF Impulse Capture
Detects and records high-frequency impulse events up to 4MHz.
Supraharmonics
Measures conducted emissions in the 2kHz to 150kHz frequency range.
No Software Required
Built-in web access, reports and email functions reduce the need for installed software.
Automated Event Reports
Generates event evidence for engineering review and customer / utility discussion.
Industrial Protocols
Supports integration with SCADA, BMS, EMS and monitoring systems.
Environmental Correlation
Optional sensors allow correlation with temperature, humidity, pressure and vibration.
Power Quality Monitoring
PQube 3 records power quality events with waveform and RMS detail, enabling practical root-cause analysis. It is suitable for both permanent monitoring and portable investigation.
| Power Quality Function |
Purpose / Value |
| Voltage Sags / Dips |
Records short-duration voltage reduction events that can cause machine trips, PLC resets, VFD faults and production interruption. |
| Voltage Swells |
Records short-duration overvoltage events that can affect sensitive electronics, power supplies and control systems. |
| Interruptions |
Captures short or long interruptions and stores event records for investigation. |
| Frequency Events |
Records over-frequency and under-frequency events for grid and generator-related investigations. |
| Harmonics |
Measures voltage and current harmonics according to IEC 61000-4-7 Class 1, up to the 50th harmonic. |
| Flicker |
Supports flicker measurement according to IEC 61000-4-15. |
| Unbalance |
Supports voltage and current unbalance measurements using IEC, GB and ANSI methods. |
| Supraharmonics |
Measures conducted emissions in the 2kHz to 150kHz range. |
| High-Frequency Impulses |
Detects and records high-frequency impulse events up to 4MHz. |
Energy and Power Monitoring
Class 0.2 kWh
Supports high-precision energy monitoring and power consumption review.
4-Quadrant Energy
Monitors imported and exported active, reactive and apparent energy.
Power Factor
Tracks true power factor and displacement power factor depending on configuration.
Peak Averages
Supports single-cycle, 1-minute, 15-minute and selected interval averaging.
Long-Term Trends
Supports daily, weekly and monthly trends, energy accumulators and load-duration information.
Multi-Load Monitoring
Can be applied to multiple feeders or loads depending on model and current channel configuration.
Electrical, Environmental and Process Inputs
| Input / Data Type |
Typical Use |
| Voltage Channels |
Three-phase, single-phase, split-phase and phase-to-phase power quality monitoring. |
| Current Channels |
Load current, feeder current, multi-load energy monitoring and equipment-level power visibility. |
| AC/DC Analogue Channels |
DC voltage, DC current, process values and auxiliary measurement points. |
| Environmental Sensors |
Temperature, humidity, atmospheric pressure and acceleration / vibration monitoring with optional probes. |
| Process Parameters |
Flow, RPM, pressure, fuel level, water flow, solar irradiance and other external sensor inputs where applicable. |
Communication and Data Access
Built-In Web Access
Remote access through built-in web server using secure web communication where configured.
Email Notification
Automatic email alerts and reports after disturbances or at configured trend intervals.
Industrial Protocols
Supports Modbus/TCP, DNP3, SNMP with traps and BACnet for system integration.
File Access
Supports FTP / secure FTPS and HTTP / HTTPS data access depending on configuration.
Time Sync
Supports NTP / SNTP time synchronisation for accurate event timestamping.
Storage Options
Supports external storage, USB port and cloud storage options depending on setup.
Technical Highlights Summary
| Parameter |
Specification / Capability |
| Product Type |
Class A power quality analyser, energy meter and real-time sensor. |
| Power Quality Class |
IEC 61000-4-30 Class A. |
| Power Quality Sampling |
512 samples per cycle at 50Hz / 60Hz. |
| Energy Accuracy |
Class 0.2 kWh accuracy. |
| Harmonics |
IEC 61000-4-7 Class 1 up to the 50th harmonic. |
| Flicker |
IEC 61000-4-15 flicker measurement. |
| Supraharmonics / Conducted Emissions |
2kHz to 150kHz measurement range. |
| High-Frequency Impulse |
Impulse detection and recording up to 4MHz. |
| Memory and Storage |
External storage up to 32GB, USB port and cloud storage options. |
| Instrument Power |
24Vac, ±24 to 48Vdc, PoE compatible, or optional 100 to 240Vac / 120 to 370Vdc modules. |
| Protocols |
Modbus/TCP, DNP3, SNMP with traps, BACnet, FTP / HTTP, secure FTPS / HTTPS and email. |
| Mounting Options |
DIN rail, enclosure, wall-mount, rack-mount, portable and custom installation options. |
Selection note: Final PQube 3 configuration should consider voltage level, current sensor type, required event reporting, communication protocol, storage requirement, environmental sensors and whether the installation is permanent, portable or panel-mounted.
Applications and Best-Fit Sites
- Manufacturing plants
- Semiconductor facilities
- Data centres
- Hospitals
- Airports
- Utilities
- Water infrastructure
- Renewable energy systems
- UPS systems
- Critical feeders
- MV / LV incomers
- Production lines
- Power quality investigations
- IoTWatt 4.0 projects
Why PQube 3 for Critical Sites?
Find Root Cause
Helps identify whether disturbances are from utility supply, internal loads, switching, faults or sensitive equipment behaviour.
Evidence-Based Reports
Stores event records, waveforms and trends that can be used for engineering and management review.
Energy and PQ Together
Combines power quality monitoring with energy, power and load profile information.
Correlate Site Conditions
Environmental and process inputs help correlate power events with site operating conditions.
Automated Alerts
Email reports and alerts reduce delay between event occurrence and engineering review.
System Integration
Integrates with SCADA, BMS, EMS, IoTWatt 4.0 and industrial monitoring platforms.
Integration with IoTWatt 4.0
PQube 3 can be integrated into site monitoring architecture using Ethernet and industrial communication protocols. In IoTWatt 4.0 projects, PQube 3 can provide high-quality event data, power quality records and energy measurements for dashboards, alerts, reports and incident investigation.
- Modbus/TCP integration
- Power quality events
- Waveform evidence
- Voltage sag / swell review
- Energy monitoring
- Critical feeder dashboards
- Automated event reporting
- Production event correlation
- Power quality management
- Digital energy audit data
- EECA reporting support
Recommended Deployment Checklist
- Confirm monitoring objective
- Confirm voltage system
- Confirm CT / current sensor type
- Confirm permanent or portable use
- Confirm required PQ standards
- Confirm event thresholds
- Confirm storage requirement
- Confirm email reporting
- Confirm time synchronisation
- Confirm Ethernet settings
- Confirm Modbus/TCP or protocol need
- Confirm environmental sensors
- Confirm IoTWatt 4.0 integration
- Test event recording and reporting
PQube 3 Supply, Setup and IoTWatt 4.0 Integration
Saturn Pyro supports Powerside PQube 3 power quality analyser applications for manufacturing plants, semiconductor facilities, data centres, utilities, healthcare facilities, critical infrastructure, power quality investigations and IoTWatt 4.0 monitoring projects in Malaysia.
Enquire Now
Lihat detail lebih lanjut tentang Saturn Pyro Sdn Bhd