HVAC Performance Check

分类: Testing & Commissioning (T&C) for New AHUs 当前有货
欲了解更多详情,请游览我们的官方网站 eakon.com.my

详情

In the 2026 Malaysian regulatory landscape, an HVAC Performance Check has transitioned from a routine maintenance task to a statutory requirement. Under the Energy Efficiency and Conservation Act (EECA) 2024, commercial and industrial buildings are now legally mandated to prove their systems are operating within specific energy intensity benchmarks.

At EKG (Malaysia) SDN BHD, our performance checks are engineered to be Statutory-Compliant and Data-Driven, ensuring your facility remains BOMBA-Ready and energy-optimized.


1. Statutory Energy Audit (EECA 2024 Compliance)

As of 2026, the Suruhanjaya Tenaga (ST) requires building owners to monitor and report their Building Energy Intensity (BEI). A performance check is the primary tool for this.


2. Mechanical & Thermodynamic Verification

We use high-precision, NATA-traceable instruments to map the "Actual vs. Design" health of your AHU.

Checkpoint Engineering Metric Purpose
Airflow Traverse $m^3/h$ (measured via Pitot tube) Ensures the AHU meets the thermal load without over-ventilating (wasting energy).
Enthalpy Map $\Delta h$ (On-coil vs. Off-coil) Validates that the cooling coil is removing moisture effectively in KL's 90% humidity.
ESP Verification External Static Pressure (Pa) Identifies "chokepoints" or leaks in the AHU Ducting Service.
Delta T Verification Chilled Water $\Delta T$ Ensures a high temperature difference (min $5.5^\circ\text$) to optimize chiller plant COP.

3. Hygiene & IAQ Audit (DOSH 2026)

Indoor Air Quality (IAQ) is now a primary focus for DOSH (JKKP). A performance check must include a biological safety review.


4. Life-Safety Integration (BOMBA 2026)

A performance check is incomplete without verifying the "Fire Mode" functionality required for your annual Fire Certificate (FC).

  1. FAMS Interface: We trigger a simulated signal from the Fire Alarm Monitoring System to witness the Automatic Fire Signal AHU Shut-off.

  2. Damper Response: We physically verify that all Motorized Fire Dampers (MFDs) reach a 100% smoke-tight seal.

  3. Acoustic Signature: We ensure the unit operates within the NC 30-35 range. Excessive noise can interfere with building emergency voice-alarm (VA) systems.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your facility's HVAC system ready for the 2026 statutory audit?

Contact EKG (Malaysia) SDN BHD today for a professional HVAC Performance Check & Compliance Audit.

Would you like to discuss how we can map your current AHU data directly into your Energy Management System (EnMS) for automated reporting?

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD