Fire Rated Ducting & AHU Connections: Statutory Standards 2026

In the 2026 Malaysian engineering landscape, the interface between Fire Rated Ducting and the Air Handling Unit (AHU) is a critical point of statutory audit. Under the Uniform Building By-Laws (UBBL) 2026 and MS 2586:2026, the continuity of a building's fire compartmentation must not be compromised by HVAC penetrations. As of February 3, 2026, BOMBA inspectors specifically target "Breakaway Connections" and "Fire-Rated Canvas" as high-fail items during Fire Certificate (FC) inspections.

At EKG (Malaysia) SDN BHD, we ensure your ducting systems are Sterile, Silent, and Statutory-Compliant.


1. The Statutory Requirement: MS 2586:2026

Ductwork passing through different fire compartments must be "Fire Rated" or enclosed in a fire-rated shaft.


2. Engineering the AHU-to-Duct Connection

The point where the rigid ducting meets the AHU must account for both vibration isolation and fire safety.

A. Fire-Rated Flexible Connectors (Canvas)

Standard dark green canvas is a major statutory violation in 2026.

B. Breakaway Duct Connections

To protect the integrity of the Motorized Fire Dampers, the duct connection to the damper sleeve must be designed to "fail safely."


3. Materiality & Installation Benchmarks

Component 2026 Technical Requirement Engineering Purpose
Duct Gauge Minimum 1.2mm (G18) for Smoke Spill Ensures structural integrity under high-heat/negative pressure.
Fire-Rated Paint/Wrap Certified 120-minute Intumescent Maintains "Insulation" rating to prevent heat ignition on the "safe" side.
Expansion Clearance 6mm to 10mm Gap at Wall Allows the damper/sleeve to expand without warping the fire wall.
Intumescent Mastic BOMBA-Approved Fire-Stop Seals the annulus between the duct sleeve and the structural opening.

4. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU duct connection a fire-safety asset or a statutory liability? Contact EKG (Malaysia) SDN BHD today for a specialized Fire Rated Ducting & Connection Audit.

Are you installing fire-rated ducting for a new commercial high-rise or retrofitting an existing facility for its 2026 Fire Certificate renewal?

更多 EKG M & E SDN BHD 相关资料
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD