Yes. Dimensionally identical to the Parker 943718Q — same OD, length, flow direction, and double open-end configuration. Drops straight in with no modification required.
A nominal rating captures roughly 50–90% of particles at the stated size — and varies between manufacturers. An absolute rating means 99.5%+ capture efficiency, verified by ISO 16889 multi-pass testing of the media. This filter is 20 Micron; B20 = 200, B26.6 = 1000.
Yes — independently verified. SONA's 20 Micron; B20 = 200, B26.6 = 1000 microglass media is tested to ISO 16889 with a Beta ratio of BX = 200, matching or exceeding performance in both efficiency and dirt-holding capacity.
Change the Parker 943718Q element when differential pressure reaches 25 PSID, or at your OEM service interval — typically every 500–2,000 operating hours depending on system load and contamination levels. Do not wait until the bypass valve activates.
Full Specs
O.D.
2.76"
I.D. Top
1.6"
I.D. Bottom
Bypass Valve = 25 PSID
Length Overall
8.45"
Construction Type
Bypass Valve = 25 PSI, Microglass, Single Open End