Features & Specifications :
| Product specifications | HE generator 20/35kHz |
| Power supply | 190-265V, single phase, 50-60Hz |
| Size | Height 370×Width 127XLength 415mm |
| Weight | 20kHz 2000&3000W: 8.0kg 35kHz 900W: 7.5kg |
| Electrical box color | RAL 3020 red |
| Display | 4 lines x 20 characters LCD screen, with backlight |
| LED light stick | 20 LEDs display the peak value of welding output |
| LED | 4 LED lights to show the status of the electric box |
| Keyboard | 26 buttons (including ON/OFF button) |
| Microgenerator | 16-bit/20MHz |
| Microprocessor | 16-bit/16MHz |
| Analog/Digital Signal Converter | 12 bits |
| Power measurement | Real time |
| Frequency range | 20kHz: 19700-20150Hz 35kHz: 34700-35150Hz |
| Automatic FM | Real-time, can automatically adjust to the normal frequency range |
| Power loss measurement | Optional before welding, after welding, close this function |
| Stroke measurement | Real time, error ±0.01mm |
| Rated output power | 20kHz: 2000/3000W 35kHz: 900W |
| Maximum output power | 10% greater than rated output power |
| Internal amplitude | Adjustable range 60%-100% (unit 5%) |
| External amplitude | Adjustable range 60%-100% (unit 5%) |
| Amplitude measurement | External measuring sensor (optional) |
| Operating mode | Time/energy/ultrasonic stop vibration/power/stroke mode, etc. |
| Time pattern | The setting range is 0.005-9.999s |
| Energy pattern | The setting range is 0-99999.99Ws |
| Ultrasonic vibration stop mode | Built-in |
| Trip mode | The setting range is 0-500.00mm, with an error of ±0.01mm |
| Power mode | Adjustable range 0-100% |
| Limit value mode | The required energy/time/power/stroke/number of workpieces can be set |
| Pressure trigger start | Adjustable range 0-6.5bar/sensor 4-20mA |
| Time triggered start | The setting range is 0-9.999s |
| Proportional valve analog signal | Adjustable range 0-10V |
| Multi-stage pressure setting (used with proportional valve) | 5 levels of pressure setting |
| Power output controller | Adjustable range 0-5V |
| Press controller | Two-hand start switch & compressor air pressure |
| Counter | The setting range is 0-999999999 |
| Stroke deceleration control | Adjustable range 0-500mm |
| Internal power supply | 24VDC/400mA with voltage regulation and short circuit protection |
| Enter | Optocoupler 20-28VDC/max.7mA |
| Output | Optocoupler 22-26VDC/max.250mA, with short-circuit protection |
| Emergency stop | Screen display message |
| Error message displayed | Screen display/hardware output |
| PLC communication interface | Various digital input and output signals |
| PC communication interface | RS232, data can be exported |
| Database | Can store up to 99 sets of welding parameters |
| External selection database | 4xDigital/16xDigital HEX/RS232 interface |
| Software updates | BDE interface |
| Buzzer | A sound will be emitted when the keyboard confirmation key is pressed and an error message appears |
| Test program (service program) | All input and output signal hardware tests |
| Connecting plug | All are D-sub |
| Pin password | 4-digit lock code to prevent parameter settings from being modified at will |
| Main power switch | Back of electrical box |
| Menu language | English/German/Spanish/French/Italian etc. |
| Suitable temperature | Operating temperature -5°C~45°C / Storage temperature -20°C~60°C |
| Design and manufacturing place | Switzerland |
Malaysia