Fire Safe AHU

Category: BOMBA Certified AHU Installation Available
For more information, visit our official website at eakon.com.my

Description

Fire Safe AHU: Statutory Safety Standards 2026

In the 2026 Malaysian regulatory landscape, a Fire Safe AHU is a mechanical asset engineered to prioritize life safety by preventing the spread of smoke and fire. Under the Fire Services Act 1988 (Act 341) and the Uniform Building By-Laws (UBBL) 2026, air handling equipment is classified as a critical "Active-Passive" life safety component.

At EKG (Malaysia) SDN BHD, we specialize in the installation and certification of Fire Safe AHUs to ensure your facility remains Sterile, Silent, and Statutory-Compliant.


1. The Statutory "Kill-Signal" Protocol

A Fire Safe AHU must be interlocked with the building's Fire Alarm Monitoring System (FAMS). This integration ensures that the unit does not act as a "smoke pump" during an emergency.


2. Engineering Hardware for Fire Safety

To be truly "Fire Safe," the AHU must maintain the integrity of the building’s fire compartments using certified hardware.

Component 2026 Technical Standard Engineering Purpose
Motorized Fire Dampers MS 558:2024 Certified Automatically seals duct penetrations in fire-rated walls in under 20 seconds.
Duct Smoke Detectors Photoelectric / Interlocked Provides localized detection to trigger the shut-off sequence.
Fire-Rated (FR) Cabling MS 2116 Compliant (Class C) Ensures the shut-off signal survives high-heat events during a fire.
Non-Combustible Casing Class 0 Insulation Prevents the unit itself from contributing to the plant room's fire load.

3. Passive Fire-Stopping & Compartmentation

A Fire Safe AHU installation includes "passive" measures that prevent fire migration through structural openings.


4. Verification & The 2026 Statutory Audit

Certification of a Fire Safe AHU is finalized during a physical witness test by a BOMBA officer:

  1. Smoke Injection Test: We inject non-toxic smoke into the return air plenum to verify the response time of the Automatic Fire Signal AHU Shut-off.

  2. Damper Integrity Audit: Verification that all motorized dampers revert to a "Closed" position upon loss of power.

  3. Digital Twin (LOD 500): All fire-safety coordinates and component certifications are uploaded to your building’s Digital Birth Certificate for the mandatory 5-year periodic audit.


5. Why Partner with EKG (Malaysia) SDN BHD?

Is your AHU installation safe enough to pass a 2026 BOMBA audit? Contact EKG (Malaysia) SDN BHD today for a specialized Fire Safe AHU & Statutory Audit.

Are you implementing these safety standards for a new Grade-A office development or as part of a fire-safety upgrade for an existing facility?

More detail about EKG M & E SDN BHD
EKG M & E SDN BHD
EKG M & E SDN BHD ACMV Services Kuala Lumpur (KL), Fire Protection Services Selangor, Electrical Engineering Contractor Malaysia ~ EKG M & E SDN BHD
Contact Us flagMalaysia