A Circulator Pump is a specific type of centrifugal pump used to move water, or other fluids, in a closed-loop system. Unlike a booster pump, which must lift water against gravity, a circulator pump only needs to overcome the friction of the pipes (the "head loss"). This makes them the heart of modern HVAC systems, ensuring that chilled or heated water is delivered consistently to every corner of a building.
EKG (Malaysia) Sdn Bhd specializes in the sizing, installation, and maintenance of high-efficiency circulator pumps for commercial and industrial cooling applications across Selangor and the Klang Valley.
In central cooling systems, circulator pumps move chilled water from the chiller’s evaporator to Air Handling Units (AHUs) and Fan Coil Units (FCUs).
Primary Pumps: Maintain a constant flow through the chiller to prevent freezing.
Secondary Pumps: Use Variable Frequency Drives (VFDs) to adjust flow based on the building’s actual cooling demand.
These pumps circulate water between a water-cooled chiller (or WCPU) and a rooftop cooling tower to reject heat from the building into the atmosphere.
Common in luxury hotels and hospitals, these pumps ensure that hot water is immediately available at the tap by constantly circulating it through a dedicated return line.
To ensure 24/7 reliability, several key components must be monitored and serviced:
Mechanical Seal: This prevents water from escaping the pump along the rotating shaft. A "weeping" seal is a sign of imminent failure and potential motor damage.
Impeller: The rotating component that provides the "push." We inspect impellers for pitting caused by cavitation and scaling from poor water treatment
Bearings: These support the shaft. Loud grinding or high-pitched screeching indicates the bearings have reached the end of their service life.
Coupling: Connects the motor to the pump. In larger base-mounted units, this requires Laser Shaft Alignment to prevent vibration.
| Symptom | Potential Root Cause | EKG Solution |
| Pump runs but no flow | Air-lock in the system or closed valves. | System bleeding and valve verification. |
| Excessive Noise/Vibration | Misalignment or bearing wear. | Laser Alignment and bearing replacement. |
| Motor Trips Breaker | Short circuit or seized impeller. | Winding insulation test and mechanical check. |
| Leaking at Shaft | Failed mechanical seal. | Precision seal replacement with silicon carbide. |
System-Wide Integration: We don't just look at the pump; we understand how it interacts with your Building Management System (BMS) and HVAC controllers.
ISO-Certified Excellence: All repairs and installations follow strict international engineering standards to ensure safety and durability.
Energy Optimization: We specialize in retrofitting old pumps with VFDs to reduce your building's monthly electricity costs by up to 30%.
Rapid Local Support: Strategically located in Selangor to provide quick on-site assistance for commercial facilities.
A failing circulator pump can lead to hot zones, high electricity bills, or a complete system shutdown. Trust EKG (Malaysia) Sdn Bhd to provide the technical expertise and rapid response your facility requires.