This test shall be carried out in accordance with ISO 20653 with the following parameters:
| Operating mode of DUT | Intermitting between 1 min operating mode II.a and 1min operating mode II.c |
| Required degree of protection | As specified in the component requirement specification |
Test Standard: LV124
This test shall be carried out in accordance with ISO 20653 with the following parameters:
| Operating mode of DUT | Operating mode II.a |
| Required degree of protection | IPX9K |
| Water pressure | The steam jet shall have a minimum pressure of 10000 kpa (100 bar) as measured directly at the nozzle |
| Water temperature | 80 ℃ |
| Test procedure | The DUT shall be subjected to the water jet from every freely accessible direction around the vehicle |
| Number of DUTs | 6 |
Malaysia