Specifications
            
                
                - OMD-2008 SERIES BILGE ALARM: .
 
                
            
         
        
        Description
        5 ppm + 15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)
Specification
 
Range (measurement & indication)
0 - 30 ppm, Trend up to 50ppm
 
Range (IMO specification)
0 - 15 ppm (according IMO regulations)
 
Accuracy
better than IMO MEPC.107(49)
 
Electrical power supply
24V - 240V, AC or DC, Automatic Voltage Selection
 
Electrical power consumption
< 10 VA
 
Sample
Oily water from separator outlet, 0,1 - 4 l/min
 
Sample temperature range
+1°C  to +65°C
 
Sample connections
R 1/4'' Female
 
Alarm 1 & 2 Set Points
1 - 15ppm (independently adjustable)
 
Alarm 1 operating delay for annunciation
1 - 540 sec
 
Alarm 2 operating delay for control
1 - 10 sec
 
Alarm contacts
2 independently adjustable switchover contacts
 
Alarm contact operation mode
De-energized in Alarm State
 
Alarm contact ratings
3A, 240V each
 
Alarm output
0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
 
Ambient temperature
+1°C to +55°C
 
Class of protection
IP 65
 
Dimension
360 x 240 x 100 mm (WxHxD)
 
 