| Item | Data | |||
| APPROVAL | ||||
| Test standard | IEC/ EN61984:2009 / UL1059 | |||
| Pitch [mm] | 2.5 | |||
| Poles | 02-12P | |||
| EN61984 Test data | VDE certificate NO. 40025627 | |||
| Rated insulation voltage [V] | 250 | |||
| Rated current [A] | 5 | |||
| Rated connection capacity(solid/stranded) [mm²] | 0.2-0.5 | |||
| Surge voltage category/pollution degree/material group | II/2/I | |||
| Rated impulse voltage [KV] | 2.5 | |||
| UL1059 Test data | UL File Number E228872 | |||
| Use group | B | C | D | |
| Voltage [V] | 150 | 150 | 150 | |
| Current [A] | 4 | 4 | 4 | |
| Rated connection capacity (solid/stranded) [AWG] | 26-20 | |||
| General data | ||||
| Inflammability classUL94 | V0 | |||
| Ambient temperature [℃] | -40~+105 | |||
| Relative humidity | 5%-95% | |||
| Inspection standard | MIL-STD-105E II | |||
| AQL | 0.65 | |||
| Warranty | 12 months | |||
| Material and plating | ||||
| Housing | PA66 | |||
| Contact | Copper alloy,Sn plated | |||
| Spring | Stainless steel | |||
| Wire connecting | ||||
| Recommended stripping length 8mm; | ||||
| 1.For solid wire, stripping wire to the appointed length ,press button and insert the wire. | ||||
| 2.For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | ||||